Meriam M200LS-DN2000 Lab Standard Smart Manometer, Differential Pressure, 0-2000" H2O Range, + or - 0.01% Accuracy Full Scale, 1/8" NPT Female Connection, Battery Operated
The Meriam M200LS-DN2000 Lab Standard digital manometer has a non-isolated differential sensor to compare the pressure between two sources. The meter has a measuring range of 0 to 2000 inches of water. NIST traceable accuracy of + or - 0.01% includes all effects of linearity, repeatability, hysteresis, and temperature from 59 to 86 degrees F (15 to 30 degrees C). The 1/8" female NPT connection is composed of 316L stainless steel and brass parts and has Viton O-rings for use with clean, dry, non-corrosive gases. Engineering units include inches of water, psi, mm of Hg, inches of Hg, mbar, bar, kPa, kg/cm2, cm of H2O, and user-selectable scaling. The meter can be field-recalibrated for zero, span, and linearity with one- or five-point calibration. Leak test feature allows users to view Min/Max pressure values and calculate the leak rate per minute in pressure units when pressure testing pneumatic systems. Exponential damping has a user-selectable time constant from 0.1 to 25 seconds to minimize the effect of pulsating pressures. The keypad has a sealed membrane to protect the instrument from contamination, and five dome contact-style buttons to ease operation. The two-line LCD shows 5 significant digits, and has contrast adjustment for use in a variety of lighting situations. The two-stage backlight provides visual indication of over-range measurements. The display can read out in any of eleven pressure units, or can be linearly scaled for user-selectable scaling. The meter has a square root flow function to display flow rate in user-defined units. An adjustable damping feature minimizes the effects of pulsating pressures. A Min/Max function captures the extremes of pulsating or varying pressure signals, and a Hold function freezes the display at any point of interest. Auto Record retains up to 240 readings for future recall. The meter has automatic shut-off at user-selectable times of 10, 20, 30, 45 or 60 seconds to extend battery life. The polycarbonate case is permanently static dissipative to provide ESD protection. The meter includes a rubber boot to protect against accidental bumps or drops.
H is height, the vertical distance from the lowest to highest point; W is width, the horizontal distance from left to right; D is depth, the horizontal distance from front to back. Manometers measure the pressure of a liquid or gas. They are used in laboratory, medical equipment, engineering, automotive, and heating, ventilation, and air-conditioning applications. Manometers measure any combination of gauge, absolute, or differential pressures. Gauge pressure is the amount of pressure in a system relative to the ambient pressure, absolute pressure is the amount of pressure in a system relative to an absolute vacuum, and differential pressure is the difference between two pressures. Analog manometers are composed of columns of liquid, and they use gravity and the liquid's density to calculate pressure. Because they have no moving parts, analog manometers do not require re-calibration. Digital manometers have pressure sensors that are connected to a system with a hose to provide a digital readout of the amount of pressure present in a system. They use microprocessors to calculate pressure, and they require periodic calibration to help ensure accuracy. Meriam manufactures process measurement instrumentation including manometers, pressure gauges and transmitters, hand pumps, and flow indicators for the oil and gas, chemical, petrochemical, and automotive industries. The company, founded in 1911, is headquartered in Cleveland, OH. What's in the Box?
|
-
Digital differential manometer with 0 to 2000 inches of water measuring range and non-isolated differential sensor compares pressure between two air or gas sources
-
1/8" female NPT connection composed of 316L stainless steel and brass parts and Viton O-rings for use with clean, dry, non-corrosive gases
-
NIST traceable accuracy of + or - 0.01% of full scale including all effects of linearity, repeatability, hysteresis, and temperature from 59 to 86 degrees F (15 to 30 degrees C)
-
Engineering units include inches of water, psi, mm of Hg, inches of Hg, mbar, bar, kPa, kg/cm2, cm of H2O, and user-selectable scaling
-
Instrument provides field recalibration for zero, span, and linearity; Min/Max pressure values; calculates leak rate per minute; automatically saves results; and provides exponential damping with user-selectable time constant
Product Information Specifications for Meriam M200LS-DN2000 Lab Standard Smart Manometer, Differential Pressure, 0-2000" H2O Range, + or - 0.01% Accuracy Full Scale, 1/8" NPT Female Connection, Battery Operated Below:
Manufacturer | Meriam Process Technologies |
Brand | Meriam |
Model | ZM200LS-DN2000 |
Package Weight | 2.25 pounds |
Package Size | 6.6 x 3.5 x 3.5 inches |
Units in Package | 1 |
Join Our Community!
Like what you see? Get a FREE account and start posting, sharing, and discovering more!
Have Questions? Contact Us!
Find out the answers to your questions by contacting us. We look forward to hearing from you!