4.3 out of 5 stars with 26 reviews
Hanna Instruments HI8410 Dissolved Oxygen Controller, 0.1 mg/L, +/-1%, -10 to 50 Degree C
List Price
$499.06
Our Price
$494.07
Savings
1% OFF
* Pricing Information Updated Less Then A Minute Ago
The HI 8410 is a panel mounted dissolved oxygen controller that is used to maintain and monitor the concentration of DO in a wide range of industrial process applications. The HI 8410 uses a Galvanic probe that typically requires less maintenance than a Polarographic style making it ideal for long term monitoring. The set point for controlling the activation of a relay is adjusted manually by the user. An alarm relay is also manually adjustable and is based upon a tolerance from the programmed set point. Calibration is single set point and can be done in zero oxygen solution. Specifications: Range- 0.0 to 50.0 milligrams per liter (ppm) O2, 0 to 600 percent O2,-5.0 to 50.0 degree C. Resolution- 0.1 milligrams per liter or 1 percent (O2)/0.1 degree C. Accuracy at 20 degree C- +/-1 percent of reading (O2)/+/-0.2 degree C. Calibration- manual, one point, in saturated air. Temperature Compensation- automatic, from-5 to 50 degree C (23 to 122 degree F). Salinity compensation- 0 to 51 g/L (resolution 1 g/L). Probe (not included)- HI 76410/4 with 4 m (13.1') cable or HI 76410/10 with 10 m (32.8') cable. Recorder output- 0 to 20 mA or 4 to 20 mA (isolated). Setpoint and alarm relay- 1, isolated, 2A, max. 240V, resistive load, 1,000,000 strokes. Setpoint range- 1 to 600 percent O2; 0.1 to 50.0 milligrams per liter (ppm) O2. Alarm range- 1.0 to 5.0 milligrams per liter (ppm) O2. Hysteresis range- 0.5 to 2.4 milligrams per liter (ppm) O2. Dosing control- Off/Auto/On with selection switch. Over dosing Control- adjustable, from 5 min to 60 min with knob or disable by wire strap- on rear panel. Backlight- continuous on. Power supply- 115 VAC +/-10 percent or 230 VAC +/-10 percent; 50/60 Hz. Enclosure- flame retardant ABS body and front panel; transparent splash-proof front cover. Environment- -10 to 50degree C (14 to 122degree F); RH max 95 percent non-conndensing. Panel cutout- 5.6" x 2.7". |
-
Extended range to 50 mg/L (ppm)
-
Manual single point calibration
-
Selectable 0-20 or 4-20 mA output
-
Low maintenance Galvanic DO probe, backlit LCD
-
Operational mode LED indicators; transparent splash-proof cover included
Product Information Specifications for Hanna Instruments HI8410 Dissolved Oxygen Controller, 0.1 mg/L, +/-1%, -10 to 50 Degree C Below:
Manufacturer | Hanna Instruments |
Brand | Hanna Instruments |
Model | HI8410 |
UPC | 613468064882 |
Item Weight | 2.2 pounds |
Item Size | 50 x 50 x 50 inches |
Package Weight | 2.4 pounds |
Package Size | 5.2 x 4.2 x 4.2 inches |