Product Details
4.1 out of 5 stars with 24 reviews

Dwyer CO2/RH/Temp Transmitter, CDTR-2D4F4, Duct Mount, 20K Ohm Thermistor Output


List Price
$252.53
Our Price
$250.00
Savings
1% OFF
* Pricing Information Updated Less Then A Minute Ago

Availability:

In Stock / Usually ships in 1-2 business days


Select Quantity:


  Add to Cart

Dwyer® Series CDTR Carbon Dioxide, Relative Humidity and Temperature Transmitters reduce the number of sensors mounted on a wall or in a duct. By combining CO2, RH, and temperature in one device, system integrators are able to lower installation time of mounting multiple housings, while lowering material cost at the same time. Even with the three sensors combined into a single unit, replacement cost is not increased due to the pluggable nature of the humidity sensor, which allows it or the temperature to be replaced at a fraction of the cost of a new CO2 transmitter. Like our popular Series CDT Carbon Dioxide Transmitter, a single-beam dual-wavelength non-dispersive infrared (NDIR) sensor is used to automatically correct the measurement in both occupied* and unoccupied buildings against light source aging effects. The single-beam dual-wavelength sensor technology provides the highest level of accuracy compared to Automatic Baseline Correction methods which can unintentionally shift the calibration based on CO2 levels and barometric pressure conditions. In order to achieve a higher level of accuracy, the Series CDTR also includes digital barometric pressure adjustment and the ability to field-calibrate the sensor. Universal outputs for both carbon dioxide and relative humidity allow users to select the transmitter output to be 4 to 20 mA, 0 to 5 VDC, or 0 to 10 VDC to work with virtually any building management controller. Additionally, passive thermistor or RTD sensor can be ordered for a temperature output. Push buttons are standard on all configurations of the transmitters for access to the menu structure, but wall mount configurations can be ordered without the buttons.
  • Barometric Pressure Dependence: 0.13% of reading per mm of Hg.

  • Temperature Output: 20 K? NTC thermistor.

  • Accuracy: ±40 ppm + 3% of reading (CO2); ±2% (RH).

  • Ambient Operating Temperature: 32 to 122°F (0 to 50°C).

  • Power Requirements: 16 to 35 VDC or 19 to 28 VAC.

Product Information   Specifications for Dwyer CO2/RH/Temp Transmitter, CDTR-2D4F4, Duct Mount, 20K Ohm Thermistor Output Below:

Manufacturer Dwyer Instruments, Inc.
Brand Dwyer
Item Weight 0.35 pounds
Units in Package 1

Join Our Community!

Like what you see? Get a FREE account and start posting, sharing, and discovering more!

Have Questions? Contact Us!

Find out the answers to your questions by contacting us. We look forward to hearing from you!