|
|
-
4.1 of 5.0 with 339 Reviews
SALE PRICE: $48.79 10% OFF
Manufacturer: Honeywell
Brand: Honeywell
Model: TL8230A1003
Color: White
Manufacturer: Honeywell
Brand: Honeywell
Model: TL8230A1003
Color: White
' Line Voltage Thermostat, Heating Only Digital, 7 Programs per Week, Switch Type DPST, Switch Action Open on Rise, Number of Switches 1, Sensor Type Thermistor, Digital 7 Day Programmable, 15 Amps Max; 3600 Watts at 240 VAC, 3120 Watts at 208 VAC, For Use With Electric Baseboards, Convectors and Fan Forced Heaters (Resistive Rated Loads), Color White, Application Heating, 7 Programs per Week, Digital LCD Display, 208 to 240VAC, 208 to 240VAC, 15A, 15A, 15, 2, UL, CSA '
-
4.1 of 5.0 with 26 Reviews
SALE PRICE: $49.99 67% OFF
Manufacturer: Tekpower
Brand: Tekpower
Model: DT9602R
Color: Orange & Black
Manufacturer: Tekpower
Brand: Tekpower
Model: DT9602R
Color: Orange & Black
|
The Tekpower DT9602R is a professional fully featured true RMS multimeter with RS232 Optical interface. It measures AC/DC voltage, current, resistance, capacitance, frequency, temperature, duty cycle and etc.. It has many nice features such as flexible auto power offer, data hold, back light and a lot more. It even has a test lead holder for your convenience. Specifications DC voltage: 600mV/6/60/600V ± 0.5%, 1000V ± 0.8%, AC voltage: 6/60/600V ± 0.75%, 750 ± 1.2%, DC current: 600µA/6/60/600mA ± 1.5%, 6/10A ± 2.0%, AC current: 600µA/6/60/600mA ± 2.0%, 6/10A ± 2.5%, Resistance: 600Ω/6/60/600KΩ ± 1.0%, 6/60MΩ ± 2.0% Capacitance: 4nF ± 5.0%, 40/400nF/4/40µF ± 3.0%, 400µF ± 5.0%, 4mF ± 20.0%, Temperature: -50 °C--+400°C ± 0.75% ± 3 °C, -58 °F--+752°F ± 0.75% ± 5 °F, Frequency: 1Hz - 10 MHz ± 0.1%, Duty Cycle: 0.1% - 99.9% ± 2.5%, Diode Check, Continuity buzzer. Accessories include A pair of test leads with shrouded plugs and capped tips, Optical RS232 cable, K-type Thermo probe, User manual. Optional RS232 - USB cable sold separately.
-
4.1 of 5.0 with 35 Reviews
SALE PRICE: $49.99 1% OFF
Manufacturer: DUOYI
Brand: Yi Duo
Model: DY30-1
Manufacturer: DUOYI
Brand: Yi Duo
Model: DY30-1
Features:Three test voltages, measure insulation resistance to 20G¦¸AC voltage measurement to 600VLow resistance buzzerData hold, auto rangeLow battery warningComplete with test leads, heavy duty carry casePackage includes:1 * DY30-1 Insulation Resistance Tester1 * Accessory kit (Insulation Test Leads and Leather Case)1 * Gift Box
-
4.1 of 5.0 with 22 Reviews
SALE PRICE: $49.99 1% OFF
Manufacturer: Sinometer
Brand: Sinometer
Model: MS2102
Manufacturer: Sinometer
Brand: Sinometer
Model: MS2102
The Mastech MS 2102 Clamp meter is an invaluable tool for technicians and electricians. It offers you an impressive array of innovative features such as Data Hold, Auto-zero, Polarity indication, low battery indication and Auto power-off. Better yet, it comes with a Tekpower wire splitter, which will become handy when it comes to measuring current, AC or DC.
Specifications:
High Accuracy and Resolution with 3999 Display, 3 3/4 Digits LCD Dsiplay
DCV:0-400V/600V ±1%,
ACV:0-400/600 V±2.0%,resolution: 1V,
ACA:0-40A/400A ±2.0%,
DCA: 0- 40A- 400A ±2.0%,
R:0-400±0.1%,
Input impedance: 10M Ohm,
Continuity:
-
4.1 of 5.0 with 24 Reviews
SALE PRICE: $50.00 1% OFF
Manufacturer: Kanomax
Brand: Kanomax
Model: 3887-04
Manufacturer: Kanomax
Brand: Kanomax
Model: 3887-04
Kanomax spare Isokinetic probe for model 3887 handheld laser particle counter.
-
4.1 of 5.0 with 50 Reviews
SALE PRICE: $50.32 1% OFF
Manufacturer: Cal Test Electronics
Brand: Cal Test Electronics
Model: CT2062-10-0
Color: Black
Manufacturer: Cal Test Electronics
Brand: Cal Test Electronics
Model: CT2062-10-0
Color: Black
Standard 4mm straight banana plugs on both ends. With 18 AWG (0.75 sq mm) silicone jacketed lead wire. IEC rating: 33 VAC/70 VDC. Voltage, maximum: 1200 V AC/DC. Current, maximum: 12 A. Resistance, maximum: 55 mohm. Jacket material: silicone. Conductor area: 0.75 sq mm. Wire gauge: 18 AWG. Stranding: #195 x 0.07mm diameter. Lead outside diameter: 3.7mm. Temperature: -20 to +80 degree C. RoHS (2002/95/EC) compliant. Black color. 10cm length.
-
4.1 of 5.0 with 6 Reviews
SALE PRICE: $50.62 1% OFF
Manufacturer: Cal Test Electronics
Brand: Cal Test Electronics
Model: CT3212
Color: Black/Red
Manufacturer: Cal Test Electronics
Brand: Cal Test Electronics
Model: CT3212
Color: Black/Red
Pair of black and red digital multimeter probe bodies with 4mm contact tips. The 4mm contact tips are covered with a spring loaded sheath for added protection. Unscrew the tip to access and replace the fuse. Probe bodies are marked with the rating of the internal fuse. The rear of the probe bodies has 4mm sheathed banana jacks for test lead connection. Convenient black and red pair. Replaceable ceramic fuse: 500 mA/660 V, 6mm diameter by 32mm length. IEC rating: 1000 V CAT II. Voltage (fuse): 1000 V. Maximum current (fuse): 500 mA. Interrupting rating (fuse): 50 kA. Temperature: -20 to +40 degree C. RoHS compliant.
-
4.1 of 5.0 with 28 Reviews
SALE PRICE: $51.00 1% OFF
Manufacturer: ALL-TEST Pro
Brand: ALL-TEST Pro
Manufacturer: ALL-TEST Pro
Brand: ALL-TEST Pro
ALL-TEST PRO 31 Protective Instrument Glove
-
4.1 of 5.0 with 28 Reviews
SALE PRICE: $51.99 23% OFF
Manufacturer: Supco
Brand: Supco
Model: EM60
Color: Multicolored
Manufacturer: Supco
Brand: Supco
Model: EM60
Color: Multicolored
|
The Supco EM60 dual-input digital differential thermometer with probes is for use in applications requiring a broad range of temperature measurements including superheat measurements, food service applications, and heating, ventilation, and air-conditioning system maintenance. When using a K-type thermocouple, it measures temperature from -200 to 1300 degrees C (-328 to 2372 degrees F). When using a J-type thermocouple, it measures temperature from -200 to 1200 degrees C (-328 to 2192 degrees F). It has a best accuracy of + or - 0.1% of reading + 0.7 degree C (1.4 degrees F). The thermometer accepts K-type thermocouple probes, which have a broader temperature measurement range than a thermistor sensor but provide lower accuracy, or J-type probes, which provide higher accuracy but have a narrower temperature measurement range than a K-type probe. This dual-channel thermometer has two inputs for connecting temperature probes (two probes are included), allowing the operator to measure the temperature of two samples at one time. The LCD screen can display the current temperature measurement for either input channel as well as the difference between the two channels. It can also display the highest or lowest temperature reading for a session. The operator can choose to display readings in degrees Fahrenheit or Celsius. The thermometer's internal memory can record up to five sets of minimum, maximum, and differential temperature data for future recall. The hold function keeps a measurement on the display so it can be recorded. The operator can set high and low temperature alarms to sound when measurements exceed or drop below the preset limits. The thermometer operates on three AAA batteries (included), and the thermometer will automatically turn off after 20 minutes of non-use to conserve battery life. A low-battery indicator alerts the operator when the batteries need to be replaced. Two K-type wire probes are included with the thermometer. A lanyard is included to help protect against accidental drops, and a sensor ...
-
4.1 of 5.0 with 34 Reviews
SALE PRICE: $52.50 1% OFF
Manufacturer: OMRON
Brand: Omron
Manufacturer: OMRON
Brand: Omron
|
[Operation/resetting system]Time-limit operation/self-resetting [Time-limit contact]4PDT [Time ranges]0.04 s to 3 h [Supply voltage]100 to 120VAC(50/60Hz) [Mounting]Surface/DIN-track mounting(with socket) Time Ranges [Rated time]30 min [Time setting range]1 to 30 min [Item] H3Y-4 [Rated supply voltage *2 [Reset voltage] 10% min. of rated supply voltage *2 [Power consumption] Relay ON: Approx. 1.8 VA (1.6 W) at 120 VAC, 60 HzRelay OFF: Approx. 1 VA (0.6 W) at 120 VAC, 60 Hz [Control outputs] 3 A at 250 VAC, resistive load (cos phi = 1)The minimum applicable load is 1 mA at 1 VDC (P reference value).Contact materials: Au-clad + Ag-alloy *1. Do not use the output from an inverter as the power supply. Refer toSafety Precautions for All Times for details. *2. Use the Timer within 90% to 110% of the rated supply voltage (95% to110% for 12 VDC) when using it continuously under an ambient operating temperature of 50 deg.(C). *3. Set the reset voltage as follows to ensure proper resetting. 100 to 120 VAC:10 VAC max. 200 to 230 VAC:20 VAC max. 100 to 110 VDC:10 VDC max. *4. Refer to Safety Precautions for All Times when combining the Timerwith an AC 2-wire proximity sensor. *5. A diode to prevent reverse voltages is provided only on models witha DC power supply.
|
|