|
|
-
3.8 of 5.0 with 12 Reviews
SALE PRICE: $1,155.00
Manufacturer: Megger
Brand: Megger
Model: 242002-30
Manufacturer: Megger
Brand: Megger
Model: 242002-30
|
The Megger 242002 series duplex test lead with fixed-point duplex hand spikes is for use with Megger DLRO10HD, DLRO10, DLRO10X, 247000, 247001, 247002, 247100, 247101, and BT51 digital low-resistance ohmmeters. This duplex test lead measures both current and resistance when taking four-wire resistance measurements, which are more accurate than two-wire resistance measurements and allow low resistance values to be detected. The lead has a maximum test current input of 10 amp. There is 0.35" (9 mm) between the current and potential probe tips on the duplex hand spikes.A test probe, test lead, test prod, or scope probe transmits an electrical signal to a testing device for display and analysis. Designs range from simple test leads with probe-style or clamp-on tips to more complex oscilloscope probes and current detectors. Some test probes, such as basic test leads, have wires with tips for connecting to test equipment. Other test probes, such as voltage detectors, are built into the meter. Depending on what is to be tested, the probe might either be passive or have active parts that require external power to operate. Some probes require contact for testing, while some are capable of taking measurements from a distance. Some also have finger barriers, insulation, or other features to help protect the operator's hand from electrical shock and burns. Test probes are rated according to the amount of voltage, current, temperature, or other input they can measure. When choosing a test probe, the maximum amount of input that the probe can measure should match or exceed both the maximum amount that can be tested by the test equipment, as well as that of the property expected to be present in the application.Megger manufactures equipment for cable fault locating, protective relay testing, telecommunications and data integrity, and power quality testing under multiple brand names, among them Megger, Biddle, States, and AVO. The company, founded in 1889, is headquartered in Dover, England, and meets International Organization ...
-
3.8 of 5.0 with 31 Reviews
SALE PRICE: $1,250.00
Manufacturer: Megger
Brand: Megger
Model: 242011-18
Manufacturer: Megger
Brand: Megger
Model: 242011-18
|
The Megger 242011 series duplex test lead with helical spring-point duplex hand spikes is for use with Megger 247100, 247101, DLRO10HD, DLRO10, and DLRO10X digital low-resistance ohmmeters. This duplex test lead measures both current and resistance when taking four-wire resistance measurements, which are more accurate than two-wire resistance measurements and allow low resistance values to be detected. The lead has a maximum test current input of 10 amp. The helical spring-point hand spikes compress and rotate to make contact with a conductor. There is 0.4" (10 mm) between the current and potential probe tips on the duplex hand spikes.A test probe, test lead, test prod, or scope probe transmits an electrical signal to a testing device for display and analysis. Designs range from simple test leads with probe-style or clamp-on tips to more complex oscilloscope probes and current detectors. Some test probes, such as basic test leads, have wires with tips for connecting to test equipment. Other test probes, such as voltage detectors, are built into the meter. Depending on what is to be tested, the probe might either be passive or have active parts that require external power to operate. Some probes require contact for testing, while some are capable of taking measurements from a distance. Some also have finger barriers, insulation, or other features to help protect the operator's hand from electrical shock and burns. Test probes are rated according to the amount of voltage, current, temperature, or other input they can measure. When choosing a test probe, the maximum amount of input that the probe can measure should match or exceed both the maximum amount that can be tested by the test equipment, as well as that of the property expected to be present in the application.Megger manufactures equipment for cable fault locating, protective relay testing, telecommunications and data integrity, and power quality testing under multiple brand names, among them Megger, Biddle, States, and AVO. The company, founded in 1889, is ...
-
3.8 of 5.0 with 2 Reviews
SALE PRICE: $1,299.99 1% OFF
Manufacturer: Fluke Corporation
Brand: Fluke
Model: I3000 FLEX-4PK
Manufacturer: Fluke Corporation
Brand: Fluke
Model: I3000 FLEX-4PK
|
The i3000s Flex is an AC current clamp utilizing the Rogowski principle. It can be used to measure currents up to 3000A when used in conjunction with oscilloscopes, recorders or data loggers. The flexible and lightweight measuring head allows quick and easy installation in hard to reach areas. Three ranges: 30A, 300A and 3000A, 1, 10 or 100 mV/A output. Ideal for current measurement on thick and hard to reach conductors without breaking the circuit. Maximum conductor diameter 178mm. CAT III 600V safety rating. Current ranges: 30A, 300A, 3000A AC rms. Output sensitivity (AC-coupled): 100 mV, 10 mV, 1 mV per A. Load impedance: 100 kilo ohm minimum. Accuracy at +25 degree C: +/-1 percent of range (45 Hz to 65 Hz). Linearity 10 to 100 percent of range: +/-0.2 percent of reading. Noise: 8 mV AC rms (30 A), 2 mV AC rms (300A, 3000A). Frequency range: 10 Hz to 50 kHz (-3 dB). Phase error: less than +/-1 degree (45 Hz to 65 Hz), +/-10 degree (at 20 kHz). Position sensitivity with cable greater than 25 mm from the coupling: +/-2 percent of range. External field with cable greater than 200 mm from the head: +/-1 percent of range. Power supply: 2 x AA/MN 1500/LR6 Alkaline, 400 hours, low battery indicator or dedicated external power supply. Temperature coefficient: +/-0.08 percent of reading per degree C. Working voltage: 600V AC rms or DC. Head circumference: 610mm. Head cable diameter: 14.3mm. Head bend radius: 38.1mm. Cable length (head to electronics): 2m. Output connection: 0.5m cable terminated with safety BNC connector. Supplied with 4mm safety plug adapter. Operating temperature range: -20 to +90 degree C (-4 to 190 degree F) (head), -20 to +85 degree C (-4 to 185 degree F) (electronics). Storage temperature range: -40 to +105 degree C (-40 to 221 degree F) (head), -20 to +85 degree C (-4 to 185 degree F) (electronics). Operating humidity: 15 to 85 percent (non-condensing).
-
3.8 of 5.0 with 11 Reviews
SALE PRICE: $1,360.43 20% OFF
Manufacturer: Identity Music Group
Brand: Ideal
Model: 61-956
Manufacturer: Identity Music Group
Brand: Ideal
Model: 61-956
|
The Ideal 61-956 open/closed circuit tracer kit includes a rotating display, TR-958 Transmitter, RC-958 receiver, TL-956 tracer test lead set and C-956 hard carrying case. It can be used on de-energized/energized circuits from 0-600V AC/DC and will not affect GFCI's or other sensitive equipment on the line. This circuit tracer identifies circuit breakers, pinpoints opens and shorts, and can trace wires behind walls and underground. It has four modes you can use switch to depending on what your need is, those modes include: search high, search low, trace and breaker. It is the only circuit tracer with Swivel Display. The transmitter requires four AA batteries and has a battery life of 40 hours for open circuit testing and 25 hours for short circuit testing while the Receiver runs on three AA batteries and has a rated battery life of 20 hours. J. Walter Becker founded IDEAL in 1916 and made a promise that is still an important part of the way IDEAL operates today: "An IDEAL product will provide a value greater than the price paid for it. Service is a part of the product." IDEAL brings you products that make your job easier; products that you can rely on, with warranties you can trust. Every IDEAL product comes with the promise made by our founder more than 90 years ago.
-
3.8 of 5.0 with 7 Reviews
SALE PRICE: $1,500.00 1% OFF
Manufacturer: DENT Instruments
Brand: DENT Instruments
Model: EXC-U-N-C
Manufacturer: DENT Instruments
Brand: DENT Instruments
Model: EXC-U-N-C
|
The ELITEpro XC is a complete solution for pinpointing electric usage and quantifying energy usage. It is capable of measuring, storing, and analyzing electrical consumption data which is derived from the voltage and current inputs. The ELITEpro XC uses direct connections to each phase of the voltage and various interchangeable CT options such as split-core current transformers or flexible RoCoils (for large loads or large cables and buss bars) to monitor current on each phase. These meters can capture kWh/kW energy and demand data as well as virtually all relevant energy parameters for diagnostics and monitoring on three-phase or single-phase circuit installations. Electrical load diagnostic parameters, such as displacement power factor, are captured in addition to energy and demand values. The ELITEpro XC's flexibility, size, and ease-of-use make it the ideal tool for gathering detailed consumption information in commercial, industrial, government and retail environments.
-
3.8 of 5.0 with 33 Reviews
SALE PRICE: $1,730.00 1% OFF
Manufacturer: Tektronix
Brand: Tektronix
Model: AFG3021C
Manufacturer: Tektronix
Brand: Tektronix
Model: AFG3021C
Superior Performance and Versatility: With the 25 MHz AFG3021C you can choose from 12 different standard waveforms. Arbitrary waveforms can be generated up to 128 K in length at high sampling rates. On pulse waveforms, leading and trailing edge time can be set independently. External signals can be connected and added to the output signal. All instruments feature a highly stable time base with only ±1 ppm drift per year.
-
3.8 of 5.0 with 6 Reviews
SALE PRICE: $2,195.00 1% OFF
Manufacturer: Hioki
Brand: Hioki
Model: 9754
Manufacturer: Hioki
Brand: Hioki
Model: 9754
Clamp the clamp on noise sensor around the lan cable and monitor the noise Hilogger display. Measurement with the clamp on noise sensor is earth-free. The clamp on noise sensor measures noise current. The noise current level and frequency of the earth line can be measured simply, without direct contact. Because measurement requires no electrical contact, there's no need to worry about interfering with communications, electric shock or short circuits, and use is simple and safe even in active-line conditions. 1kHz to 100MHz (-3dB) band width. AC 10A (15A peak) rated current. +/-3.0 percent rdg, +/- 0.001 percent fs (fs = 10A, f=15kHz, with conductor centered in clamp) amplitude accuracy. up to f20mm measurable conductor diameter. CAT II 600V, CAT III 300V (insulated conductor) maximum rated voltage to earth. Measures 6-59/64" width by 2-23/32" height by 1-19/32" depth. 2m Cord length.
-
3.8 of 5.0 with 21 Reviews
SALE PRICE: $2,252.54 1% OFF
Manufacturer: FW BELL
Brand: FW Bell
Manufacturer: FW BELL
Brand: FW Bell
FW BELL 5180 METER, GAUSS, 1G-30kG, 0HZ-25KHZ, 1.1%
-
3.8 of 5.0 with 6 Reviews
SALE PRICE: $2,700.00 1% OFF
Manufacturer: Tektronix
Brand: Tektronix
Model: TCP0020
Manufacturer: Tektronix
Brand: Tektronix
Model: TCP0020
TCP0020 provides a maximum 20 ARMS measurement range. These probes also provide excellent accuracy to current levels as low as 10 mA, important for meeting today’s challenging current measurement needs.
-
3.8 of 5.0 with 2 Reviews
SALE PRICE: $3,090.00 1% OFF
Manufacturer: Tektronix
Brand: Tektronix
Model: TCP303
Manufacturer: Tektronix
Brand: Tektronix
Model: TCP303
TEKPROBE systems can use the TCPA300/400 Series to make proper current measurements by simply multiplying the measured output voltage on the oscilloscope by the TCPA300/400 Series range setting.
|
|