|
|
-
3.5 of 5.0 with 29 Reviews
SALE PRICE: $255.00 1% OFF
Manufacturer: COLE-PARMER
Brand: HF Scientific
Manufacturer: COLE-PARMER
Brand: HF Scientific
Turbidity standards for validation and calibration of MicroTol on-line turbidimeter
-
3.5 of 5.0 with 27 Reviews
SALE PRICE: $258.00 1% OFF
Manufacturer: COLE-PARMER
Brand: HF Scientific
Manufacturer: COLE-PARMER
Brand: HF Scientific
Replacement calibration set for MicroTPW Handheld Turbidimeter 99543-20 Includes 0.02, 10, and 1000 NTU standards
-
3.5 of 5.0 with 32 Reviews
SALE PRICE: $309.67
Manufacturer: Grant Instruments
Brand: Grant Instruments
Manufacturer: Grant Instruments
Brand: Grant Instruments
McFarland standard for DEN-1 Densitometer. Set of latex particle suspension McFarland standards (0.5/1.0/2.0/3.0/4.0), require D-16 for use.
-
3.5 of 5.0 with 17 Reviews
SALE PRICE: $489.19 69% OFF
Manufacturer: Hanna Instruments
Brand: Hanna Instruments
Model: HI88703-01
Manufacturer: Hanna Instruments
Brand: Hanna Instruments
Model: HI88703-01
|
The Hanna Instruments HI 88703-01 is a turbidity meter designed to meet EPA reporting requirements. The meter has two, three, four, or five-point calibration, can log up to 200 samples, and has automatic range selection. It operates using a 230 V/50 Hz or 115 V/60 Hz 20 W power supply and automatically shuts off after 15 minutes of non-use. The meter has a USB interface, a silicon photocell light source, and a backlit LCD screen to reduce glare. Calibration is traceable, allowing the user to check the last date, time, and points calibrated. The meter uses the Nephelometric method (90 degrees) or Ratio Nephelometric Method (90 degrees and 180 degrees), and an adaptation of the USEPA Method 108.1 and Standard Method 2130 B. Turbidity ranges are 0.00 to 9.99; 10.0 to 99.9; 100 to 4000 NTU 0.0 to 99.9; 100 to 26800 Nephelos, 0.00 to 9.99; 10.0 to 99.9; 100 to 980 EBC, with resolution 0.01; 0.1; 1 NTU, 0.1; 1 Nephelos, 0.01; 0.1, and 1 EBC when ratiometric measurements are used. Ranges are 0.00 to 9.99; 10.0 to 40.0 NTU, 0.0 to 99.9; 100 to 268 Nephelos, 0.00 to 9.80 EBC, with resolutions 0.01; 0.1 NTU, 0.1; 1 Nephelos, 0.01 EBC when non-ratio method is used. Accuracy is + or - 2% of reading plus 0.02 NTU (0.15 Nephelos; 0.01 EBC) + or - 5% of reading above 1000 NTU (6700 Nephelos; 245 EBC). The measuring mode can be set to normal, average, or continuous, to either EBC or Nephelos measuring units, and to one of several languages. Dimensions are 230 x 200 x 145 mm (9 x 7.9 x 5.7â€) with weight 2.5 Kg (88 oz.). Turbidity meters measure the loss of transparency due to suspended particles present in a solution. They are commonly used to measure the turbidity of water in both the field and laboratory. Hanna Instruments manufactures a wide variety of analytical instrumentation, including pH meters, multi-parameter meters, electrodes, chemical reagents, and buffer solutions. Founded in 1978, Hanna is headquartered in Woonsocket, RI, with subsidiaries in 32 countries. Hanna Instruments holds many firsts in the field o...
-
3.5 of 5.0 with 49 Reviews
SALE PRICE: $963.00 1% OFF
Manufacturer: Orbeco Hellige
Brand: Orbeco Hellige
Manufacturer: Orbeco Hellige
Brand: Orbeco Hellige
|
This fully portable turbidimeter is ideal for obtaining measurements in the field or laboratory. The instrument uses a "white light" source and 90° detection for accurate turbidity measurement. An auto-ranging function automatically selects the correct turbidity range for your sample. Results are shown on a large liquid crystal display, and five keys allow for simple operation. Use the included turbidity standards for easy calibration. The turbidimeter's power-efficient microcircuit design allows for long battery life. Included with the instrument are two sample cells, batteries, calibration set, operator's manual, and carrying case. Meets USEPA Standard 180.1 compliance for turbidity measurement. CE Certified. Specifications Range: 0.01 to 1100 NTU. Accuracy: ±2% of reading or 0.01 NTU (0 to 500 NTU); ±3% of reading (500 to 1100 NTU). Resolution: 0.01 NTU below 100.0 NTU; 0.1 NTU for 100.0 to 999.9 NTU; 1.0 NTU for 1000 to 1100 NTU. Power: 4 AA alkaline batteries. Battery Life: up to 5,000 tests; 7 to 10 year bulb life. Dimensions: 8.25" x 3.75" x 1.75".
-
3.5 of 5.0 with 15 Reviews
SALE PRICE: $1,144.12 24% OFF
Manufacturer: LaMotte
Brand: LaMotte
Model: 1972-EPA
Manufacturer: LaMotte
Brand: LaMotte
Model: 1972-EPA
The NEW LTC3000 is a benchtop turbidity, chlorine and color meter with wide range and high accuracy. ISO unit also available. The meter meets EPA 180.1 for turbidity and EPA 330.5 for chlorine. The turbidity range is 0-4,000 NTU with a MDL of 0.05 NTU. The free and total chlorine range is 0-10 ppm with a MDL of 0.03 ppm. The meter can store 500 data points which can be downloaded to a computer, allows 7 different languages, and runs on rechargeable batteries or a USB computer/wall adapter.
-
3.5 of 5.0 with 49 Reviews
SALE PRICE: $1,257.30 1% OFF
Manufacturer: LaMotte
Brand: LaMotte
Manufacturer: LaMotte
Brand: LaMotte
Turbidity Meter, EPA, Turbidity Range 0 to 4000 NTU, Display LCD, Auto Power Off, Turbidity Resolution 0.01, 0.1 and 1 NTU, Interface USB, Cable Length 1m, Power Source Lithium Rechargeable Batteries, Includes 0, 1, 10 NTU Standards, USB Interface Cable, Wall Charger, Carrying Case and Instructions, Manufacturers Warranty Length 2 Years Turbidity and Turbidity/Chlorine MetersCalibration solutions are available; on DrillSpot.com , search for "calibration solutions."6CAR1 and 6CAR2Feature LCD and Auto-Off. Memory: 500 points. Each includes USB cable, battery, charger, and carrying case.Turbidity accuracy: 2% below 100 NTU, 3% above Turbidity resolution: 0.01, 0.1, and 1 NTU
-
3.0 of 5.0 with 1 Reviews
SALE PRICE: $53.93 1% OFF
Manufacturer: Science First
Brand: Science First
Manufacturer: Science First
Brand: Science First
Determine the degree of visibility when a Secchi disc can't be used.
-
3.0 of 5.0 with 1 Reviews
SALE PRICE: $836.56 21% OFF
Manufacturer: Thermo Scientific
Brand: Oakton
Model: WD-35635-00
Manufacturer: Thermo Scientific
Brand: Oakton
Model: WD-35635-00
|
The Oakton 35635-00 turbidity meter T-100 kit has a waterproof and dustproof, handheld meter that floats, if dropped in liquids, and comes with calibration vials, cuvettes with light shield caps, silicone oil, lint-free cloth, and hard carrying case. It measures substance turbidity and is commonly used for water quality testing, treatment and management, and river monitoring in environmental, and process monitoring. This meter features four-point, push-button calibration for accuracy and auto-ranging from 0 to 1000 Nephelometric Turbidity Units (NTU) for ease of use. It has a sealed optical system with an infrared light source to deliver accuracy across a wide range, and a large LCD display to show readings and units of measurement. It has hold and auto-off functions, and diagnostic error messages, as well as a power-saving function to take up to 1,200 readings using one set of batteries. The meter is Ingress Protection (IP) 67-rated, for protection against solid objects or liquids. It has EPA-recognized ASTM D6855-03 compliance, and meets ISO 7027 (DIN EN 27027) method. The 35635-00 has temperature range of 0 to 50 degrees C (32 to 122 degrees F). Its turbidity range is 0 to 19.99; 20.0 to 99.9; 100 to 1000 NTU, resolution 0.01, 0.1, 1.0, accuracy + or - 2% of reading from 0 to 500 NTU, + or - 3% of reading 500 to 1000 NTU. It has four primary standards 0.02, 20.0, 100 and 800 NTU. Its dimensions are 6.50(l) x 2.75(w) x 2.00(h) inches, and it weighs approximately 1.5 lbs. Use with four AAA batteries (not included) for approximately 100 hours of continuous use. Turbidity meters use light reflection to detect the presence of matter in a liquid substance. They are commonly used for water testing, and to test for bacteria and other growth in the food and beverage industries and in environmental applications. Oakton Instruments manufactures an array of scientific instruments for research, industrial, and educational uses. Since 1991, Oakton has distributed a wide variety of instruments such as meters, electrodes, and...
-
1.0 of 5.0 with 2 Reviews
SALE PRICE: $307.00
Manufacturer: Thermo Scientific
Brand: Oakton
Model: WD-35635-50
Manufacturer: Thermo Scientific
Brand: Oakton
Model: WD-35635-50
|
The Oakton 35635-50 replacement turbidity vial set helps obtain turbidity measurements for detection of bacteria or growth in liquid substances. The set contains four, individual cuvettes filled with 0.02, 20.0, 100, and 800 NTU standards for ease of use. The cuvette lids are clearly labeled for identification, and the containers feature expiration dates and lot numbers for reliability. The 35635-50 is used with the Oakton T-100 turbidity meter. Turbidity meters use light reflection to detect the presence of matter in a liquid substance. Calibration standards help obtain accurate measurements. They are commonly used for water testing, and to test for bacteria and other growth in the food and beverage industries and in environmental applications. Oakton Instruments manufactures an array of scientific instruments for research, industrial, and educational uses. Since 1991, Oakton has distributed a wide variety of instruments such as meters, electrodes, and transmitters. Oakton is based in Vernon Hills, IL, and has facilities in Europe, Asia, and China. What’s in the Box? Calibration vials
|
|