|
|
-
4.2 of 5.0 with 34 Reviews
SALE PRICE: $127.08
Manufacturer: Cannon Instrument
Brand: CANNON Instrument
Manufacturer: Cannon Instrument
Brand: CANNON Instrument
CANNON certified viscosity standard liquid is useful for calibration and verification procedures, including but not limited to glass capillary, rotational, falling ball, and cup viscometers. Calibration or verification with a certified viscosity standard helps to ensure the reliability of measurements made with any viscometer. This listing is for each.
-
4.2 of 5.0 with 17 Reviews
SALE PRICE: $127.46
Manufacturer: TPI
Brand: TPI
Manufacturer: TPI
Brand: TPI
|
The TPI 510 is an easy to use, solar irradiance meter for measurement of not only solar radiation, but all measureable light sources including all visible light. The TPI Solar Meter is state of the art and easy to use. It is designed to measure solar power in W/m2 or BTU (ft2*h). Application Use to find the optimal angle of inclination for installing solar panels Measure light intensity through windows Determine the effectiveness of solar film / window tint Suitable for measuring the effectiveness of solar film Car windows light intensity measurement Optimal incident angle for solar panels Measurement of the sun's transmission through transparent and film glass Measuring your car headlights: Â Turn the car headlights on. Turn on the 510 solar meter, and "00.0" appears on the screen. Put the 510 down close to the headlights. Switch between high beam and low beam, and the light intensity values appear on the display. Test both the right and left headlights and write the values down for reference. (Refer to Picture 1) Measure the effect of solar insulation of your vehicle's windows: Â Press the Power button to turn the 510 solar meter on and "00.0" appears on the screen. Aim the 510 at the sun holding it close to a window and the intensity value appears on the display. Open the window and aim the device at the sun. Compare the value against that acquired when the window is closed to understand the efficiency of the window's solar film. (Refer to Picture 1) Â NOTE??ÃœWhen the light sensor cover is not attached "CAP" is indicated. Make sure that it is attached. If performing the zero adjustment after powering on, several digits may not disappear. In this case, perform the zero adjustment again. Measure the solar insulation effect of your house's windows: Close the window. Press the Power button on your 510 solar meter, and "00.0" comes up on the screen. Put the device close to the window and aim it at the sun
-
4.2 of 5.0 with 44 Reviews
SALE PRICE: $128.08 16% OFF
Manufacturer: Thermo Scientific
Brand: Oakton
Model: WD-35607-53
Manufacturer: Thermo Scientific
Brand: Oakton
Model: WD-35607-53
Each conductivity/TDS cell features a 3-ft cable and a two-band platinum sensor. Glass body cells have a temperature range of 0 to 100°C.
-
4.2 of 5.0 with 3 Reviews
SALE PRICE: $129.00
Manufacturer: Huanyu Instrument
Brand: Huanyu Instrument
Manufacturer: Huanyu Instrument
Brand: Huanyu Instrument
|
Huanyu Instrument Huanyu Instrument® mainly provides instruments and tools. We provide voltage customized services, specific requirements can be contacted by email, we will respond promptly.After your order is confirmed, the product usually takes 7--13 business days to arrive to your hand. Product description ITO glass has the property of low sheet resistance and high transmittance, and it is widely used in the production and research of OLED, OPV, electrochromic device, e-book, electrochemistry, Low-Temperature Solution-Processed Perovskite Solar Cells, et al. Technical Datas Size:100*40*1.1mm Sheet Resistance:82% Thickness of the ITO Layer:1000+/-200A Luster of the ITO Layer:Golden Color of the Cross Section:Light Blue Package included:25 pcs ITO glass Friendly Reminder When purchase, please confirm the product is from our Huanyu Instrument, otherwise we can't ensure the quality and after-sale service.We will try our best to provide you the best product and service, welcome to buy our product.
-
4.2 of 5.0 with 29 Reviews
SALE PRICE: $129.00 1% OFF
Manufacturer: COLE-PARMER
Brand: Cole-Parmer
Manufacturer: COLE-PARMER
Brand: Cole-Parmer
|
All flowmeters come with correlation data sheets for water and air at standard temperature and pressure (STP). We can also supply calibration data for oxygen, nitrogen, hydrogen, helium, CO2, argon, other liquids and gases, and for conditions other than STP-call our Application Specialists for more information. Compact size makes these ideal for tight measuring areas Clear polycarbonate front shield magnifies scale 16%. A vertical tangential locator line ensures hairline accuracy in reading float position. Each flowmeter consists of a heavy-walled glass flowtube mounted in an anodized aluminum frame with white acrylic back plate (1/8' thick). Minimum flow rate is less than one tenth of the maximum flow value in the ordering table. Select a flowmeter with a high-precision valve for superior flow rate control-ideal for low-flow applications or for any application where you need precise flow control. The 16-turn high-precision valve features a nonrising stem to more accurately hit your desired set point.
-
4.2 of 5.0 with 6 Reviews
SALE PRICE: $131.40 1% OFF
Manufacturer: COLE-PARMER
Brand: Cole-Parmer
Manufacturer: COLE-PARMER
Brand: Cole-Parmer
science-lab-conductivity-meters
-
4.2 of 5.0 with 15 Reviews
SALE PRICE: $133.00 1% OFF
Manufacturer: Hedland Flow Meters
Brand: Hedland Flow Meters
Manufacturer: Hedland Flow Meters
Brand: Hedland Flow Meters
|
The EZ-View series flow meter is a rugged, low cost direct reading industrial class flow meter that is simple to install. It can be mounted (installed) in any position from vertical to horizontal without costly flow straighteners or other special plumbing. Constructed of high impact polysulfone plastic, the EZ-View product line offers excellent structural integrity and chemical compatibility with a wide range of industrial chemicals.Automatically signals alarm, if flow is too high or too lowModels available for AC or DC power supplyPolysulfone bodies for standard applicationsEasy to installEasy flow limit adjustmentRelatively insensitive to shock and vibrationWithin +/-1% repeatabilityLow cost+/-5% full scale accuracyLength includes end fittingDo not use pipe dopeUse Teflon tape onlyUse with plastic fittings only. Brand Name|Hedland#MFR Part Number|H621-607/H526-008#UNSPSC|41112501#Item|Flow Meter#Type|Variable Area#Series|EZ-View, H621#Connection Size|1 Inch#Flow Rate|1 - 7 gpm#Pressure Rating|325 psi#Connection Type|NPTF Male#Maximum Viscosity|4.2 - 108 cSt#Mounting Type|All Position#Temperature Rating|32 - 250 deg F#Dimensions|5-1/4 Inch Length#Material|Polysulfone#Standard/Approvals|ANSI/ASME B1.20.1#Application|Water Line, Commercial Buildings, Irrigation and Seal Water, For 1.0 Specific Gravity Water Media
-
4.2 of 5.0 with 13 Reviews
SALE PRICE: $133.65 25% OFF
Manufacturer: Thermo Scientific
Brand: Oakton
Model: WD-35608-94
Manufacturer: Thermo Scientific
Brand: Oakton
Model: WD-35608-94
For use with CON 2700 benchtop meter
-
4.2 of 5.0 with 2 Reviews
SALE PRICE: $134.77
Manufacturer: Varsal, Inc.
Brand: Varsal
Model: 450-332-Q100
Manufacturer: Varsal, Inc.
Brand: Varsal
Model: 450-332-Q100
Varsal manufactures UV-VIS-NIR spectrophotometer cells and cuvettes, including micro-cells. Our unique fire-fused production technology assures long lasting, easy to clean, high performance cells. Varsal cells can be used with all commonly used spectrophotometers to measure absorbance or transmission and they comply with all international standards. Depending on the spectral range to be analyzed, Varsal spectrophotometer cells are available in optical glass, quartz and IR quartz glass. Our technical ability to produce cells that meet the demanding specifications of instrument manufacturers is only surpassed by Varsal's customer service and on-time delivery. Wavelength zone: >800 newton meters. Percentage transmission: >80%@2730 newton meters. Matching tolerance: within 0.3%@2730 newton meters
-
4.2 of 5.0 with 15 Reviews
SALE PRICE: $137.74 1% OFF
Manufacturer: Hanna Instruments
Brand: Hanna Instruments
Model: HI8936DN
Manufacturer: Hanna Instruments
Brand: Hanna Instruments
Model: HI8936DN
|
The Hanna Instruments HI 8936DN conductivity transmitter is designed for use with the HI 7635, HI 7638, or HI 3001 platinum conductivity potentiometric probe and an HI 8931 controller (all sold separately), for constant offsite monitoring of conductivity and temperature. Direct connection to the transmitter to the probe provides a positive electrical connection that eliminates signal loss over long distances. Circuitry in the transmitter and a built-in temperature sensor on the probe provide automatic temperature compensation (ATC). The transmitter has a range of 0 to 199.9 microsiemens/cm, and can be wall-mounted at any convenient location close to the measurement site. The transmitter requires external power to the 4 to 20mA current loop. Protecting the transmitter inside a case is recommended to minimize thermal drifts, particularly for outdoor measurements.SpecificationsConductivity (EC) range0 to 199.9μS/cmAccuracy range at 20 degrees C/68 degrees F+ or - 2% of full scale (excluding probe error)CalibrationManual, 2 point, with offset and slope trimmersConductivity probeHI 7635 for in-line applications (not included)Recorder output4 to 20mA, not isolated, max 500 ohmTemperature compensationFixed or automatic, 0 to 50 degrees C (32 to 122 degrees F) with Β=2%/degrees CProtection ratingIP65Environment0 to 50 degrees C/32 to 122 degrees FWeight1kg/2.2lb.Dimensions165 x 110 x 71mm/6.5 x 4.3 x 2.8 inches (H x W x D)H is height, the vertical distance from the lowest to highest point; W is width, the horizontal distance from left to right; D is depth, the horizontal distance from front to back. Conductivity meters, also known as electrical conductivity (EC) meters, measure the ability of a solution or material to conduct an electrical current. This measurement helps determine if the solution is, for example, contaminated or contains too much saline. In general, pure solutions, such as distilled water, have low conductivity. More saline- or nutrient-rich solutions, such as seawater or fertilizers, have high co...
|
|