|
|
-
4.6 of 5.0 with 45 Reviews
SALE PRICE: $88.63
Manufacturer: Starrett
Brand: Starrett
Manufacturer: Starrett
Brand: Starrett
Starrett 659G UPRIGHT BASE POST
-
4.6 of 5.0 with 11 Reviews
SALE PRICE: $93.94 6% OFF
Manufacturer: Tuthill
Brand: Fill-Rite
Model: KIT800FPP
Manufacturer: Tuthill
Brand: Fill-Rite
Model: KIT800FPP
Built into every fuel transfer pump, chemical transfer pump and meter is over 50 years of experience—and the pride and workmanship associated with the moniker Made in USA. We use only the most durable materials to insure long life and dependability. Fill-Rite and Sotera branded products deliver superior performance time and time again, regardless of the application or installation. Tuthill Transfer Systems manufactures fluid transfer pumps and meters under the Fill-Rite brand. The company, founded in 1927, is headquartered in Fort Wayne, IN.
-
4.6 of 5.0 with 377 Reviews
SALE PRICE: $95.40 27% OFF
Manufacturer: Fluke Corporation
Brand: Fluke
Model: Fluke 323
Color: Multicolored
Manufacturer: Fluke Corporation
Brand: Fluke
Model: Fluke 323
Color: Multicolored
The Fluke true-rms clamp meter is a great clamp meter for general, grab-and-go troubleshooting needs. The Fluke 323 323-AMZN is ideally suited for current measurements up to 400 a in tight cable compartments.
-
4.6 of 5.0 with 44 Reviews
SALE PRICE: $96.12 6% OFF
Manufacturer: Rice Lake
Brand: Rice Lake
Manufacturer: Rice Lake
Brand: Rice Lake
|
The Rice Lake metric stainless steel precision test weight meets American Society for Testing and Materials (ASTM) Class 4 specifications, has a 7.95 density, and is designed for a variety of weighing operations. The weight can be adjusted by attaching other weights to the screw-knob. The weight is constructed of stainless steel for stability, resistance to corrosion, and low magnetic susceptibility. The set includes a precision test weight, a handling glove, and a protective case. The weight meets ASTM E617, Class 4 specification for use as a reference standard for calibrating semi-analytic balances, and for student use.Calibration weights are used to measure the weight or mass of an object using a balance or scale, or to calibrate other weights or instruments. Calibration weights can be certified or uncertified. Certified weights meet strict guidelines for accuracy and can usually be recertified. Certified weights are used in labs where a high degree of accuracy and repeatability is required. Uncertified weights are used where a lower degree of accuracy is required, including student laboratories, rough weighting operations, and measuring force. Hooked and slotted weights are often used to measure pressure, torque, and tensile strength, and to demonstrate basic laws of physics. Calibration weights differ from lab weights, which are general purpose weights used to hold an object in place, similar to a paperweight. Science education products incorporate applied math and science principles into classroom projects. Teachers in pre-K, elementary, and secondary classrooms use science education kits and products alongside science, technology, engineering, and math (STEM) curriculum to demonstrate STEM concepts and real-world applications through hands-on activities. Science education projects include a broad range of activities, such as practical experiments in engineering, aeronautics, robotics, energy, chemistry, physics, biology, and geology.Rice Lake Weighing Systems manufactures weight-related and process-control...
-
4.6 of 5.0 with 26 Reviews
SALE PRICE: $97.46 1% OFF
Manufacturer: Mitutoyo
Brand: Mitutoyo
Model: 616197-541
Manufacturer: Mitutoyo
Brand: Mitutoyo
Model: 616197-541
|
The Mitutoyo grade AS-1 square gage block is made of ceramic, has its nominal length engraved in inches, and is supplied with a Mitutoyo inspection certificate that states that the block meets American Society of Mechanical Engineers (ASME) B89.1.9-2002 grade standard for flatness, length, parallelism, and surface finish. The inspection certificate specifies the deviation of the individual block from its nominal length. Gage blocks are commonly used to calibrate fixtures and precision instruments in workshop, inspection, and dimensional metrology applications, to inspect tools such as mounting tools, cutters, fixtures, and mechanical parts, and in the gage manufacturing process itself. This grade AS-1 gage block is commonly used for workshop and inspection applications to calibrate fixtures and precision instruments, to inspect a variety of tools such as mounting tools, cutters, fixtures, and mechanical parts, and for gage manufacturing applications. It is made of ceramic, which resists corrosion, abrasion, and burrs, can withstand high temperatures without melting (high thermal expansion resistance), and provides dimensional stability. This gage block has a square base for accurate wringing, to attain a height reference standard, and for the ability to make a dedicated inspection jig. Nominal length is measured in inches, and is indicated with laser-etched, black characters. The length of a gage block is usually slightly shorter than its stamped nominal length, to account for the thin layer of oil or wring film used when two or more blocks are wrung together. An identification number is laser-etched on the block for traceability. The block has a depth of 0.95 inches. It comes in a carrying case with a padded, formed interior. This gage block is supplied with a Mitutoyo inspection certificate [National Institute of Standards in Engineering (NIST)-traceable] that the block meets ASME B89.1.9-2002 standard for flatness, length, parallelism, and surface finish. Gage blocks (also called gauge blocks, Hoke blocks, Jo...
-
4.6 of 5.0 with 4 Reviews
SALE PRICE: $98.11 1% OFF
Manufacturer: Mitutoyo
Brand: Mitutoyo
Model: 616145-521
Manufacturer: Mitutoyo
Brand: Mitutoyo
Model: 616145-521
|
The Mitutoyo grade 00 square gage block is made of ceramic, has its nominal length engraved in inches, and is supplied with a Mitutoyo inspection certificate that states that the block meets American Society of Mechanical Engineers (ASME) B89.1.9-2002 grade standard for flatness, length, parallelism, and surface finish. The inspection certificate specifies the deviation of the individual block from its nominal length. Gage blocks are commonly used to calibrate fixtures and precision instruments in workshop, inspection, and dimensional metrology applications, to inspect tools such as mounting tools, cutters, fixtures, and mechanical parts, and in the gage manufacturing process itself. This grade 00 gage block is commonly used within a controlled environment as a reference standard for setting high-precision measuring equipment, to calibrate low-grade gage blocks, and to inspect the accuracy of gages, mechanical parts, and tools. It is made of ceramic which resists corrosion, abrasion, and burrs, can withstand high temperatures without melting (high thermal expansion resistance), and provides dimensional stability. This gage block has a square base for accurate wringing, to attain a height reference standard, and for the ability to make a dedicated inspection jig. Nominal length is measured in inches, and is indicated with laser-etched, black characters. The length of a gage block is usually slightly shorter than its stamped nominal length, to account for the thin layer of oil or wring film used when two or more blocks are wrung together. An identification number is laser-etched on the block for traceability. The block has a depth of 0.355 inches. It comes in a carrying case with a padded, formed interior. This gage block is supplied with a Mitutoyo inspection certificate [National Institute of Standards in Engineering (NIST)-traceable] that the block meets ASME B89.1.9-2002 standard for flatness, length, parallelism, and surface finish. Gage blocks (also called gauge blocks, Hoke blocks, Jo blocks, slip gages, and...
-
4.6 of 5.0 with 8 Reviews
SALE PRICE: $98.52
Manufacturer: Fungilab
Brand: Fungilab
Model: J136
Manufacturer: Fungilab
Brand: Fungilab
Model: J136
VISCOSITY STANDARD OIL RT10 Rotational viscometers standard oil.
-
4.6 of 5.0 with 31 Reviews
SALE PRICE: $100.00
Manufacturer: Fluke
Brand: Fluke
Model: 4615511
Manufacturer: Fluke
Brand: Fluke
Model: 4615511
HDMI cable helps the users view the infrared images and videos on devices such as Television or projector.
-
4.6 of 5.0 with 24 Reviews
SALE PRICE: $100.40 15% OFF
Manufacturer: Fowler
Brand: Fowler
Manufacturer: Fowler
Brand: Fowler
Features Simplify set-up applications on all machine and inspection operations. Adjustable from 4.5" to 8" Quick-acting height adjustment. Fine adjust ring for easy leveling. Height locking ring Lifting capacity 2000 lbs. (approx.)
-
4.6 of 5.0 with 9 Reviews
SALE PRICE: $102.30 5% OFF
Manufacturer: Ohaus
Brand: Ohaus
Model: 80780278
Manufacturer: Ohaus
Brand: Ohaus
Model: 80780278
|
The Ohaus metric, stainless steel calibration weight meets International Organization of Legal Metrology (OIML) Class E2 specifications and designed for calibrating other weights, or electronic balances and scales. The weight is constructed of stainless steel for stability, resistance to corrosion, and low magnetic susceptibility. The weight meets OIML R111 Class E2 specifications for use as a reference standard calibrating other weights, and calibrating high precision analytical balances with readabilities as low as 0.1mg to 0.01mg. The National Voluntary Laboratory Accreditation Program (NVLAP) accredits laboratories for compliance with ISO/IEC 17025 on the basis of their ability to meet the technical requirements set forth in NIST Handbook 150-2, and can provide accreditation to ANSI/NCSL Z540-1-1994. NVLAP calibrations and certifications meet all ISO, FDA, GMP, GLP, DOD, ANSI/NCSL Z540-1 and Nuclear requirements and are traceable to NIST. Procedures and processes used to generate this multi-page certificate, as well as its format and content, are prescribed by NVLAP. The document contains customer name & address, date of calibration, equipment and standards used in the calibration, accuracy class, true mass value (mass in a vacuum), “As Found†mass correction (for recalibration), “As Left†mass correction, uncertainty of measurement process (uncertainty to tolerance ratios are guaranteed), environmental conditions during test, construction and density of the weight, calibration procedure, and a statement of traceability to NIST. Mutual recognition arrangements include The International Laboratory Accreditation Cooperation (ILAC), The Asia Pacific Laboratory Accreditation Cooperation (APLAC) and The National Cooperation for Laboratory Accreditation (NACLA). Calibration weights are used to measure the weight or mass of an object using a balance or scale, or to calibrate other weights or instruments. Calibration weights can be certified or uncertified. Certified weights meet strict guidel...
|
|