|
|
-
3.8 of 5.0 with 4 Reviews
SALE PRICE: $182.00
Manufacturer: Opticon
Brand: OPTICON
Model: 13084
Manufacturer: Opticon
Brand: OPTICON
Model: 13084
Opticon OPI3601
-
3.8 of 5.0 with 18 Reviews
SALE PRICE: $208.85
Manufacturer: Multiquip
Brand: Multiquip
Model: 35-402
Manufacturer: Multiquip
Brand: Multiquip
Model: 35-402
Multiquip gbb85d balloon bag standard only globug 300/400 watt. Glare-free. Used for road construction, emergency repairs, backyard parties, special events, and more. Quick and easy setup. The balloon inflates in less than 30 Seconds. Holds 9 inch. By 31.5 inch. Optional message strip. Replacement balloon for 300 watt or 400 watt globug balloon lights.
-
3.8 of 5.0 with 37 Reviews
SALE PRICE: $213.00 1% OFF
Manufacturer: Hanna Instruments
Brand: Hanna Instruments
Model: HI96761
Manufacturer: Hanna Instruments
Brand: Hanna Instruments
Model: HI96761
|
The HI 96761 meter measures the traces of total chlorine (cl2) content in drinking water samples. This meter uses an exclusive positive-locking system to ensure that the cuvette is in the same place every time it is placed into the measurement cell. Chlorine is integrated into water supplies in it’s molecular form for the purpose of destroying unwanted microorganisms. HI 96761 is supplied with sample cuvettes with caps (2), 9V battery and instruction manual. 0.000 To 0.500 milligrams per liter range. 0.001 milligrams per liter resolution. +/-0.020 milligrams per liter +/-3 percent of reading at the rate of 25 degree C. Tungsten lamp light source. Light detection: silicon photocell with narrow band interference filter at the rate 525 nm. Power supply 9V battery. Auto-off: after 10 minutes of non-use in measurement mode; after 1 hour of non-use in calibration mode; with last reading reminder. Environment: 0 to 50 degree C (32 to 122 degree F); RH max 95 percent non-condensing. Measures 7-19/32" length by 4-3/32" width by 2-11/16" height. 12.7oz Weight. Method: adaptation of the method 330.5 and standard method 4500-CL G.
-
3.8 of 5.0 with 26 Reviews
SALE PRICE: $218.50 1% OFF
Manufacturer: Greenlee
Brand: Greenlee
Model: AD-108
Manufacturer: Greenlee
Brand: Greenlee
Model: AD-108
Features UCI adapters provide direct connectivity for Tempo FiberTOOLS to a wide range of industry-standard fiber optic connectors Adapter design ensures maximum accuracy and repeatability when performing critical measurements on fiber optic systems Easy to clean and use Single-mode and multimode compatible UCI adapters feature durable phosphor bronze alignment sleeve UCI (Universal Connector Interface) adapter is used on all 250/260 "A" Series Sources and 330 Series Variable Optical Attenuators When using a hybrid adapter cable, the instrument UCI adapter and one end of the hybrid adapter cable should be a commonly available connector type. (i.E. FC, SC or ST) Application: Used On All 250/260 "A" Series Sources and 330 Series Variable Optical Attenuators
-
3.8 of 5.0 with 1 Reviews
SALE PRICE: $230.00 1% OFF
Manufacturer: Hanna Instruments
Brand: Hanna Instruments
Model: HI96737
Manufacturer: Hanna Instruments
Brand: Hanna Instruments
Model: HI96737
|
Small quantities of silver are bacteriostatic or bactericidal. As a result, it is at times used in disinfection of pools and spas, as well as in water filters. The presence of silver in water is generally indicative of pollution from mainly film manufacturers, film processors and surface finishers. In fact, silver levels are closely monitored in these sectors since its presence can cause discoloration of the skin, eyes and mucous membranes. The HI96737 measures the silver content in water and wastewater in the 0.000 to 1.000 milligrams per liter (ppm) range. This instrument uses an exclusive positive-locking system to ensure that the cuvette is in the same place every time it is placed into the measurement cell. The cuvette has a very important role because it is an optical element and thus requires particular attention. It is important that both, the measurement and the calibration (zeroing) cuvettes, are optically identical to provide the same measurement conditions. 0.001 milligrams per liter (ppm) resolution. +/-0.005 milligrams per liter +/-10 percent of reading at 25 degree C accuracy. Tungsten lamp. Silicon photocell with narrow band interference filter at 575nm light detector. 0 to 50 degree C (32 to 122 degree F); RH maximum 95 percent non-condensing environment. Auto-off: after 10 minutes of non-use in measuring mode, after 1 hour of non-use in calibration mode. Measures 7.6" length by 4.1" width by 2.7" height. Adaptation of the PAN method.
-
3.8 of 5.0 with 30 Reviews
SALE PRICE: $240.50 1% OFF
Manufacturer: Greenlee
Brand: Greenlee
Model: AE2-10
Manufacturer: Greenlee
Brand: Greenlee
Model: AE2-10
Features UCI adapters provide direct connectivity for Tempo FiberTOOLS to a wide range of industry-standard fiber optic connectors Adapter design ensures maximum accuracy and repeatability when performing critical measurements on fiber optic systems Easy to clean and use Single-mode and multimode compatible UCI adapters feature durable phosphor bronze alignment sleeve UCI (Universal Connector Interface) adapter is used on all 250/260 "A" Series Sources and 330 Series Variable Optical Attenuators When using a hybrid adapter cable, the instrument UCI adapter and one end of the hybrid adapter cable should be a commonly available connector type. (i.E. FC, SC or ST) Application: Used On All 250/260 "A" Series Sources and 330 Series Variable Optical Attenuators
-
3.8 of 5.0 with 15 Reviews
SALE PRICE: $255.90 16% OFF
Manufacturer: Greenlee
Brand: Greenlee
Model: 93-172
Manufacturer: Greenlee
Brand: Greenlee
Model: 93-172
The Greenlee 93-172 is a digital light meter intended to measure light emitted from fluorescent, metal halide, high-pressure sodium and incandescent light sources. Includes Digital Light Meter 9V Battery Carrying Case Features Measures incandescent, fluorescent, metal halide, high-pressure sodium and halogen lamp output Color and cosine-corrected for enhanced accuracy Measures up to 50,000 lux Peak and data hold means no lost measurements Accessories included: (1) 9V battery and carrying case Lifetime Limited Warranty Application: For Measures Incandescent, Fluorescent, Metal halide, High-Pressure Sodium And Halogen Lamp Output
-
3.8 of 5.0 with 38 Reviews
SALE PRICE: $263.72 24% OFF
Manufacturer: Hanna Instruments
Brand: Hanna Instruments
Model: HI96719C
Manufacturer: Hanna Instruments
Brand: Hanna Instruments
Model: HI96719C
|
This meter uses an exclusive positive-locking system to ensure that the cuvette is in the same position every time it is placed into the measurement cell. It is designed to fit cuvettes with a larger neck making it easier to add both sample and reagents. The cuvettes are made from special optical glass to obtain best results. User calibration. Certified calibration and verification standards. BEPS (battery error prevention system). Timer function. Auto shut-off. GLP Features. Range: 0.00 to 2.00 milligrams per liter. Resolution: 0.01 milligrams per liter. Accuracy: +/-0.11 milligrams per liter +/-5 percent of reading at 25 degree celsius. Light source: tungsten lamp. Light detection: silicon photocell with narrow band interference filter at 525nm. Battery type/life: 1 x 9V/approx. 40 hours of continuous use; auto-off after 10 minutes of non use. Environment: 0 to 50 degree celsius (32 to 122 degree fahrenheit); RH max 95 percent non-condensing. Measures 7-19/32" length by 4-3/32" width by 2-11/16" height. Method: adaptation of the standard methods for the examination of water and wastewater, 18th ed. EDTA colorimetric method.
-
3.8 of 5.0 with 9 Reviews
SALE PRICE: $264.54 24% OFF
Manufacturer: Hanna Instruments
Brand: Hanna Instruments
Model: HI96717C
Manufacturer: Hanna Instruments
Brand: Hanna Instruments
Model: HI96717C
|
High range phosphate portable photometer kit. Kit includes photometer, 2 sample cuvettes with caps, 9V battery, scissors, cloth for wiping cuvettes, instrument quality certificate, instruction manual and rigid carrying case. Phosphates are particularly important for the growth and development of plant roots, and hence are one of the most common fertilizers used in agriculture. Phosphates are also utilized in detergents and are needed, in small quantities, for heating systems. However, high concentrations of phosphates can cause environmental pollution as they are a primary cause of eutrophication. For these reasons, it is necessary to closely monitor the phosphate levels present in both municipal and industrial waste water. 0.00 To 30.0 milligrams per liter range. 0.1 milligrams per liter resolution. +/-1.0 milligrams per liter +/-4 percent of reading at 25 degree C accuracy. Tungsten lamp. Silicon photocell with narrow band interference filter at 525nm light detector. Amino acid method, adapted from standard method for the examination of water and wastewater. 0 To 50 degree C (32 to 122 degree F); RH maximum 95 percent non-condensing environment. 9V Battery. Auto-shut off: after ten minutes of non-use in measuring mode after one hour of non-use in calibration mode with last reading reminder.
-
3.8 of 5.0 with 23 Reviews
SALE PRICE: $264.79 1% OFF
Manufacturer: Thomas Scientific
Brand: Molecular Bio Products (Auto Equip)
Model: 1426205
Manufacturer: Thomas Scientific
Brand: Molecular Bio Products (Auto Equip)
Model: 1426205
Thermo Scientific Optical Filter with 620 nm Wavelength.
|
|