4.8 of 5.0 with 13 Reviews
SALE PRICE: $29.99 1% OFF
Manufacturer: USA
Brand: Horizon
Manufacturer: USA
Brand: Horizon
This calibration weight set contains -- One 10g weight Two 20g weights One 50g weights Two 100g weights One 200g weight One 500g weight This set can be used for calibrating and testing weighing scales with capacity up to 2000g. Check your scale's manual for calibration weight requirements.
-
4.8 of 5.0 with 20 Reviews
SALE PRICE: $29.99
Manufacturer: JOHNSON CONTROLS
Brand: Johnson Controls
Manufacturer: JOHNSON CONTROLS
Brand: Johnson Controls
Calibration Tool, For Use With JCI T-4000 Series Pneumatic Thermostats, Includes Mounting Hardware.
-
4.8 of 5.0 with 22 Reviews
SALE PRICE: $35.36
Manufacturer: Troemner
Brand: Troemner
Model: 1316
Manufacturer: Troemner
Brand: Troemner
Model: 1316
200 G Class F Test weight
-
4.8 of 5.0 with 26 Reviews
SALE PRICE: $45.00 7% OFF
Manufacturer: Ohaus
Brand: Ohaus
Model: 80780318
Manufacturer: Ohaus
Brand: Ohaus
Model: 80780318
|
The Ohaus metric, stainless steel calibration weight meets International Organization of Legal Metrology (OIML) Class F1 specifications and designed for calibrating other weights, or electronic balances and scales. The weight is constructed of stainless steel for stability, resistance to corrosion, and low magnetic susceptibility. The weight meets OIML R111 Class F1 specifications for use calibrating high-precision top loading balances with a readability as low as 0.01g to 0.001g.The National Voluntary Laboratory Accreditation Program (NVLAP) accredits laboratories for compliance with ISO/IEC 17025 on the basis of their ability to meet the technical requirements set forth in NIST Handbook 150-2, and can provide accreditation to ANSI/NCSL Z540-1-1994. NVLAP calibrations and certifications meet all ISO, FDA, GMP, GLP, DOD, ANSI/NCSL Z540-1 and Nuclear requirements and are traceable to NIST. Procedures and processes used to generate this multi-page certificate, as well as its format and content, are prescribed by NVLAP. The document contains customer name & address, date of calibration, equipment and standards used in the calibration, accuracy class, true mass value (mass in a vacuum), “As Found†mass correction (for recalibration), “As Left†mass correction, uncertainty of measurement process (uncertainty to tolerance ratios are guaranteed), environmental conditions during test, construction and density of the weight, calibration procedure, and a statement of traceability to NIST. Mutual recognition arrangements include The International Laboratory Accreditation Cooperation (ILAC), The Asia Pacific Laboratory Accreditation Cooperation (APLAC) and The National Cooperation for Laboratory Accreditation (NACLA). Calibration weights are used to measure the weight or mass of an object using a balance or scale, or to calibrate other weights or instruments. Calibration weights can be certified or uncertified. Certified weights meet strict guidelines for accuracy and can usually be recertified. Certi...
-
4.8 of 5.0 with 5 Reviews
SALE PRICE: $56.69
Manufacturer: Ohaus
Brand: Ohaus
Model: 80780075
Manufacturer: Ohaus
Brand: Ohaus
Model: 80780075
|
The Ohaus metric, stainless steel precision calibration weight meets American Society for Testing and Materials (ASTM) Class 4 specifications, and is designed for use as a reference standard for calibrating other weights, or electronic balances and scales. The weight is constructed of stainless steel for stability, resistance to corrosion, and low magnetic susceptibility. A tapered neck enables the weight to be lifted with tweezers, reducing the risk of contaminants adhering to the weight. The weight meets ASTM E617, Class 4 specification for use as a reference standard for calibrating semi-analytic balances, and for student use. An optional National Voluntary Laboratory Accreditation Program (NVLAP) certificate ensures precision and traceability. The National Voluntary Laboratory Accreditation Program (NVLAP) accredits laboratories for compliance with ISO/IEC 17025 on the basis of their ability to meet the technical requirements set forth in NIST Handbook 150-2, and can provide accreditation to ANSI/NCSL Z540-1-1994. NVLAP calibrations and certifications meet all ISO, FDA, GMP, GLP, DOD, ANSI/NCSL Z540-1 and Nuclear requirements and are traceable to NIST. Procedures and processes used to generate this multi-page certificate, as well as its format and content, are prescribed by NVLAP. The document contains customer name & address, date of calibration, equipment and standards used in the calibration, accuracy class, true mass value (mass in a vacuum), “As Found†mass correction (for recalibration), “As Left†mass correction, uncertainty of measurement process (uncertainty to tolerance ratios are guaranteed), environmental conditions during test, construction and density of the weight, calibration procedure, and a statement of traceability to NIST. Mutual recognition arrangements include The International Laboratory Accreditation Cooperation (ILAC), The Asia Pacific Laboratory Accreditation Cooperation (APLAC) and The National Cooperation for Laboratory Accreditation (NACLA). Calibration we...
-
4.8 of 5.0 with 48 Reviews
SALE PRICE: $66.51 14% OFF
Manufacturer: Ohaus
Brand: Ohaus
Model: 80780322
Manufacturer: Ohaus
Brand: Ohaus
Model: 80780322
|
The Ohaus metric, stainless steel calibration weight meets International Organization of Legal Metrology (OIML) Class F1 specifications and designed for calibrating other weights, or electronic balances and scales. The weight is constructed of stainless steel for stability, resistance to corrosion, and low magnetic susceptibility. The weight meets OIML R111 Class F1 specifications for use calibrating high-precision top loading balances with a readability as low as 0.01g to 0.001g.The National Voluntary Laboratory Accreditation Program (NVLAP) accredits laboratories for compliance with ISO/IEC 17025 on the basis of their ability to meet the technical requirements set forth in NIST Handbook 150-2, and can provide accreditation to ANSI/NCSL Z540-1-1994. NVLAP calibrations and certifications meet all ISO, FDA, GMP, GLP, DOD, ANSI/NCSL Z540-1 and Nuclear requirements and are traceable to NIST. Procedures and processes used to generate this multi-page certificate, as well as its format and content, are prescribed by NVLAP. The document contains customer name & address, date of calibration, equipment and standards used in the calibration, accuracy class, true mass value (mass in a vacuum), “As Found†mass correction (for recalibration), “As Left†mass correction, uncertainty of measurement process (uncertainty to tolerance ratios are guaranteed), environmental conditions during test, construction and density of the weight, calibration procedure, and a statement of traceability to NIST. Mutual recognition arrangements include The International Laboratory Accreditation Cooperation (ILAC), The Asia Pacific Laboratory Accreditation Cooperation (APLAC) and The National Cooperation for Laboratory Accreditation (NACLA). Calibration weights are used to measure the weight or mass of an object using a balance or scale, or to calibrate other weights or instruments. Calibration weights can be certified or uncertified. Certified weights meet strict guidelines for accuracy and can usually be recertified. Certi...
-
4.8 of 5.0 with 4 Reviews
SALE PRICE: $68.00 1% OFF
Manufacturer: Mettler Toledo
Brand: Mettler Toledo
Manufacturer: Mettler Toledo
Brand: Mettler Toledo
A customized 3rd weight for your Mettler Toledo CarePacs. Use the ASTM Class 1 1 milligram weight to perform customized testing such as minimum weight determination. The 3rd weight perfectly fits into your CarePac carrying case.
-
4.8 of 5.0 with 38 Reviews
SALE PRICE: $72.80
Manufacturer: Torbal
Brand: Torbal
Manufacturer: Torbal
Brand: Torbal
100g Stainless Steel Calibration Weight. Has high precision, good stability, and great resistance to corrosion and handling damage. These weights are ideal for calibrating precision and analytical scales.
-
4.8 of 5.0 with 11 Reviews
SALE PRICE: $80.00 1% OFF
Manufacturer: Anyload
Brand: Anyload
Model: 101NH
Manufacturer: Anyload
Brand: Anyload
Model: 101NH
Load Cell for Scales.
-
4.8 of 5.0 with 27 Reviews
SALE PRICE: $86.16 21% OFF
Manufacturer: Ohaus
Brand: Ohaus
Model: 80780141
Manufacturer: Ohaus
Brand: Ohaus
Model: 80780141
|
The Ohaus metric, stainless steel electronic balance calibration weight meets American Society for Testing and Materials (ASTM) Class 4 specifications, and is designed for use as a reference standard for calibrating other weights, or electronic balances and scales. The weight has straight sides and a flat top that allows weights to be stacked. It is constructed of stainless steel for stability, resistance to corrosion, and low magnetic susceptibility. The weight meets ASTM E617, Class 4 specification for use as a reference standard for calibrating semi-analytic balances, and for student use. An optional National Voluntary Laboratory Accreditation Program (NVLAP) certificate ensures precision and traceability. The National Voluntary Laboratory Accreditation Program (NVLAP) accredits laboratories for compliance with ISO/IEC 17025 on the basis of their ability to meet the technical requirements set forth in NIST Handbook 150-2, and can provide accreditation to ANSI/NCSL Z540-1-1994. NVLAP calibrations and certifications meet all ISO, FDA, GMP, GLP, DOD, ANSI/NCSL Z540-1 and Nuclear requirements and are traceable to NIST. Procedures and processes used to generate this multi-page certificate, as well as its format and content, are prescribed by NVLAP. The document contains customer name & address, date of calibration, equipment and standards used in the calibration, accuracy class, true mass value (mass in a vacuum), “As Found†mass correction (for recalibration), “As Left†mass correction, uncertainty of measurement process (uncertainty to tolerance ratios are guaranteed), environmental conditions during test, construction and density of the weight, calibration procedure, and a statement of traceability to NIST. Mutual recognition arrangements include The International Laboratory Accreditation Cooperation (ILAC), The Asia Pacific Laboratory Accreditation Cooperation (APLAC) and The National Cooperation for Laboratory Accreditation (NACLA). Calibration weights are used to measure the weight or...
|
|