|
|
-
3.8 of 5.0 with 11 Reviews
SALE PRICE: $60.75 49% OFF
Manufacturer: Dwyer Instruments
Brand: Dwyer
Model: 476A-0
Manufacturer: Dwyer Instruments
Brand: Dwyer
Model: 476A-0
|
The Dwyer Series 476A single-pressure digital manometer is used to perform single-pressure measurements and to set supply pressures, verify pressure switch operation, adjust regulators, check pneumatic systems, and computer peripherals. The meter is suitable for use with air and compatible gases, and has an accuracy of + or - 1.5% of full scale. The extruded aluminum case provides durability. The four-digit LCD displays the pressure measurement, and a zero function nulls minor pressure differences before measuring. SpecificationsPressure typesSingleMedia typeAir and compatible gasesCase materialExtruded aluminumPressure unitsinH2O, mmH2O, bar, mbar, psi, inHg, mmHg, kPaConnection type3/16" or 1/4" inside diameter (ID) tubingMaximum pressure5 gauge psiDisplayFour-digit LCDResolution0.02 (inH2O)Temperature limits0 to 140 degrees F/-17.8 to +60 degrees CCompensated temperature limits32 to 104 degrees F/0 to 40 degrees CDimensions6-17/32 x 2-13/16 x 29/32 (H x W x D)Power9V alkaline battery (included)H is height, the vertical distance from the lowest to highest point; W is width, the horizontal distance from left to right; D is depth, the horizontal distance from front to back.Manometers measure the pressure of a liquid or gas. They are used in laboratory, medical equipment, engineering, automotive, and heating, ventilation, and air-conditioning applications. Manometers measure any combination of gauge, absolute, or differential pressures. Gauge pressure is the amount of pressure in a system relative to the ambient pressure, absolute pressure is the amount of pressure in a system relative to an absolute vacuum, and differential pressure is the difference between two pressures. Analog manometers are composed of columns of liquid, and they use gravity and the liquid's density to calculate pressure. Because they have no moving parts, analog manometers do not require re-calibration. Digital manometers have pressure sensors that are connected to a system with a hose to provide a digital readout of the amount of pressure p...
-
3.8 of 5.0 with 47 Reviews
SALE PRICE: $107.12 1% OFF
Manufacturer: COLE-PARMER
Brand: Dwyer
Manufacturer: COLE-PARMER
Brand: Dwyer
-
3.8 of 5.0 with 14 Reviews
SALE PRICE: $175.00 1% OFF
Manufacturer: Meriam Process Technologies
Brand: Meriam
Model: Z200DPG-10
Manufacturer: Meriam Process Technologies
Brand: Meriam
Model: Z200DPG-10
Migration: minor from high to low port. Sensing element: piston. Wetted parts: body material, SS spring, ceramic magnet and seals. Case material: engineered polymer. Dial size: 2.5 (square), 4.5" (round). Mounting: direct, front flange, 2" pipe and surface mounting. Maximum working pressure: 3000 Psig for Aluminum and Brass, 6000 Psig for SS. Maximum process temperature: 200 degree F. Seals: Buna-N. Lens: Plexiglass (acrylic). Connection: 1/4" NPT(F) Std. Porting: In-line. Over range protection: Up to the MAWP from high and low side. Protecting for gauge and switch: NEMA-4X / IP65. Applications includes: Filter monitoring, pump performance, level measurement, Flow, flow direction, pressure monitoring, Flow rate, strainer monitoring, condition monitoring of heating/cooling system, Air filter and collector/bag filter monitoring, collector/bag filter monitoring, blower performance.
-
3.8 of 5.0 with 7 Reviews
SALE PRICE: $182.40
Manufacturer: wonderfullife.diy
Brand: wonderfullife.diy
Manufacturer: wonderfullife.diy
Brand: wonderfullife.diy
Economic Digital Manometer Air Differetial Pressure Meter 15.000psiProduct SpecificationsRange & (Resolution):15.000 (0.001)Accuracy (10~30 C):+/-1.0% of full scaleResponse time :0.5 secondCompensated temp. range :10~30 C LCD size : 32.5 x 54(mm, HxW)Operating temp.:0~50 COperating RH%:Humidity < 80%Storage temp.:-20~50 CStorage RH%: Humidity < 90%Dimension :169x78.3x 34.4(mm,LxWxT)Weight:200gBattery:6PCS AAA batteriesStandard Package1*Meter1*manual1*warranty card2*connection hose1*hard carry caseQuality assuranceWe Guarantee this manometer is 100% original one of AZ instrument with top high quality, if there is any fake product, we will return all your money back, thanks.
-
3.8 of 5.0 with 28 Reviews
SALE PRICE: $206.77
Manufacturer: Lochinvar
Brand: Lochinvar
Manufacturer: Lochinvar
Brand: Lochinvar
Lochinvar Part Number SVC1001-MANOMETER. Description: LOCSVC1001-MANOMETER. Part Number/SKU: SVC1001-MANOMETER. Manufacturer: Lochinvar
-
3.8 of 5.0 with 2 Reviews
SALE PRICE: $230.97
Manufacturer: Kentmoore
Brand: Kentmoore
Manufacturer: Kentmoore
Brand: Kentmoore
KMJ23951 Features: -Carb Manometer.
-
3.8 of 5.0 with 14 Reviews
SALE PRICE: $271.23 1% OFF
Manufacturer: General Tools and Instruments
Brand: General Tools & Instruments
Manufacturer: General Tools and Instruments
Brand: General Tools & Instruments
Low Static, Negative Pressure.
-
3.8 of 5.0 with 1 Reviews
SALE PRICE: $292.57 5% OFF
Manufacturer: Meriam Process Technologies
Brand: Meriam
Model: ZM200LS-GI0030
Manufacturer: Meriam Process Technologies
Brand: Meriam
Model: ZM200LS-GI0030
|
Meriam's M200LS lab standard smart manometer offers the best available pressure measurement accuracy in a portable, handheld format. The NIST traceable accuracy is typically ±0.01 percent of F.S. and is independent of temperature effect over an operating temperature range of 59 degree to 86 degree F. M2 pressure sensors are available to measure gauge, differential, absolute or vacuum pressure. The display can read out in any of eleven pressure units or can be linearly scaled for special user units. Differential models offer a square root flow function to display flow rate in user defined units. An adjustable damping feature minimizes the effects of pulsating pressures. A min/ max function captures the extremes of pulsating or varying pressure signals and a hold function can freeze the display at any point of interest. Auto Record documents up to 240 readings for future recall. The M2 series can be recalibrated in the field for zero, span, and linearity. The user has the option to select a 1 point or 5 point calibration procedure. Enables users with accurate primary standards to calibrate unit locally if desired. User selectable shut-off. Programmable for disable, 10, 20, 30, 45, 60 minutes. 14 Ounce (6.5" by 3.6" by 2.25") polycarbonate, permanently dissipative, ESD protection. Sealed membrane type with 5 dome contact style buttons. 5 Significant digit LCD (0.25" high), 2 line x 16 alphanumeric characters with contrast adjustment. Two stage backlight with visual over range indication. 4 Each AA batteries providing over 100 hours of continuous use. 1/8" Female NPT, 316L SS. Storage temperature: -40 degree F to 140 degree F (-40 degree C to 60 degree C). Twice range on gauge and absolute (GI and AI) units.
-
3.8 of 5.0 with 1 Reviews
SALE PRICE: $314.00
Manufacturer: Dwyer Instruments
Brand: Dwyer
Model: 451-AF
Manufacturer: Dwyer Instruments
Brand: Dwyer
Model: 451-AF
Dwyer Durablock Series 250-AF Gages are precision machined 1" thick solid acrylic plastic, virtually unbreakable and free of distortion. The fluid bore is precision drilled to ±.0002" to assure life long accuracy. A glass spirit level is built into the body and encapsulated to prevent damage or tampering. The scale is mirror polished chrome plated brass to assure parallax free reading by alignment of the meniscus with its reflection. Safety traps are incorporated in the body to prevent loss of fluid due to pressure surges. Red and green signal flags indicate clearly when a filter change is necessary. Gages are suitable for use in ambient temperatures of -20 to 150°F. Connection fittings are positively sealed by "O" rings but easily removed for zeroing or addition of fluid. Furnished complete with instructions.
-
3.8 of 5.0 with 1 Reviews
SALE PRICE: $428.40 30% OFF
Manufacturer: Testo AG
Brand: Testo
Model: 0560 5129
Manufacturer: Testo AG
Brand: Testo
Model: 0560 5129
|
The Testo 512 Series digital manometer/anemometer measures differential pressure and air velocity of non-corrosive gases for evaluation and maintenance of HVAC systems. The meter has an accuracy of + or - 1 digit or 0.5% of full scale. It measures air velocity in m/s and fpm, and pressure in kPa, hPa, Pa, mm H2O, mmHg, psi, inch H2O, inch Hg. The two-line LCD displays pressure and air velocity simultaneously. Min/max display provides comparative data, and the display hold retains last reading when the display cannot be seen during testing. An infrared interface provides connection to a printer to print test results (printer sold separately).SpecificationsPressure typesDifferential and air flowMedia typeNon-corrosive gasCase materialABSPressure unitskPa, hPa, Pa, mm H2O, mmHg, psi, inch H2O, inch HgFlow velocity unitsm/s, fpmDisplay2-line LCDAuto Off10 minutesWeight300gDimensions202 x 57 x 42mm (H x W x D)Power9V battery, 6F22H is height, the vertical distance from the lowest to highest point; W is width, the horizontal distance from left to right; D is depth, the horizontal distance from front to back.Manometers measure the pressure of a liquid or gas. They are used in laboratory, medical equipment, engineering, automotive, and heating, ventilation, and air-conditioning applications. Manometers measure any combination of gauge, absolute, or differential pressures. Gauge pressure is the amount of pressure in a system relative to the ambient pressure, absolute pressure is the amount of pressure in a system relative to an absolute vacuum, and differential pressure is the difference between two pressures. Analog manometers are composed of columns of liquid, and they use gravity and the liquid's density to calculate pressure. Because they have no moving parts, analog manometers do not require re-calibration. Digital manometers have pressure sensors that are connected to a system with a hose to provide a digital readout of the amount of pressure present in a system. They use microprocessors to calculate pressure, and t...
|
|