|
|
-
4.0 of 5.0 with 1 Reviews
SALE PRICE: $43.90
Manufacturer: Fred V. Fowler Company, Inc.
Brand: Fowler
Model: 52-585-010-0
Manufacturer: Fred V. Fowler Company, Inc.
Brand: Fowler
Model: 52-585-010-0
The Fowler 54-565-233 High-Accuracy Ultima Bore Gauging System has a measurement range of 7.878 to 8.27" and is accurate to + or - 0.00006". Resolution is 0.00001" and the measuring depth is 3.15". The gauge has constant spring pressure for repeatability and Bower's FastFit measuring heads for rapid measurement. It uses a three-point contact system for the detection of lobing or triangular form error, and ceramic contact points provide high durability and stability with regard to thermal expansion. The Ultima system requires connection to a Sylvac or multiplexer display unit.This product has 1 year warranty offered by Fowler High Precision. If you experience any problem contact Fowler directly for warranty claims.
-
4.0 of 5.0 with 1 Reviews
SALE PRICE: $44.74
Manufacturer: Fred V. Fowler Company, Inc.
Brand: Fowler
Model: 52-057-004-0
Manufacturer: Fred V. Fowler Company, Inc.
Brand: Fowler
Model: 52-057-004-0
|
The Fowler 52-057-004 stainless steel mini vernier pocket caliper has an inch scale, a 4" measuring range, and a 0.001" graduation for measuring the inside diameter (ID) and outside diameter (OD) of holes, grooves, and tube thicknesses, and depth measurements of bores and grooves. Stainless steel construction provides durability and wear resistance, and sharp black graduations on a satin-finished bar ease reading. A locking screw secures the measurement tightly in place for accurate reading. The caliper includes a pocket-size fitted case. Vernier calipers are measuring instruments commonly used for inspection in manufacturing to provide the precise measurements of an object. A pair of jaws attached to a long beam with a marked scale is used to take inside, outside, and step measurements. An additional depth probe slides along the beam to take depth measurements. One jaw is fixed to the end of the scale, while the other jaw slides along it with gearless precision to take measurements. The main scale is engraved directly on the beam while the vernier scale is engraved on the slider mechanism. The base measurement is taken from the long beam, which provides the initial whole measurement in inches, centimeters, or millimeters. To obtain the total measurement, the base reading is added to the vernier scale reading, which provides fractional measurements in inches or millimeters. A locking mechanism provides the ability to take differential measurements for determining the difference in measurements between two objects. Compared to digital and dial calipers, vernier calipers are more durable because they do not have internal moving parts, and are less prone to inaccuracy caused by shock, debris, and other contaminants, but they can be more difficult to read than digital and dial calipers. Vernier calipers are commonly used in fields such as metalworking, mechanical engineering, machining, and carpentry.The Fred V. Fowler Company manufactures inspection and measurement instruments such as electronic indicators, calipers...
-
4.0 of 5.0 with 1 Reviews
SALE PRICE: $44.87
Manufacturer: TAZ
Brand: Generic
Color: Multi
Manufacturer: TAZ
Brand: Generic
Color: Multi
NEW DIAL INDICATOR WITH MAGNETIC BASE AEROSPACE DIAL INDICATOR MEASURING RANGE 0 TO 1 STRONG MAGNETIC BASE"
-
4.0 of 5.0 with 1 Reviews
SALE PRICE: $46.00
Manufacturer: Fred V. Fowler Company, Inc.
Brand: Fowler
Model: 52-253-102-1
Manufacturer: Fred V. Fowler Company, Inc.
Brand: Fowler
Model: 52-253-102-1
|
The Fowler 52-253-102-1 Vernier-scale micrometer has a 0.256" diameter flat anvil/spindle pair for general purpose measuring. The Vernier scale has 0.001" graduation intervals and 0.00016" accuracy for precise and accurate readings. The carbide-tipped anvil/spindle pair have hardened, precision-ground, and micro-lapped measuring faces with 0.00003" flatness and 0.00008" parallelism for accurate measurements. The positive locking lever on the spindle locks measurements in place for accurate readings. Ratchet stop applies constant force for repeatability between users. Friction-style thimbles are suitable for one-handed operation and stop turning when the spindle comes into contact with the workpiece, providing constant force for consistent measurements between operators. The ratchet stop thimble can be used independently of the thimble. It provides an audible sound and stops the spindle from turning when the spindle comes into contact with the workpiece, providing constant force for consistent measurements between operators. A satin chrome finish on the thimble and sleeve helps reduce rust and glare, providing long life, and microfine graduations help ensure accurate readings. The micrometer includes a wrench and a fitted case. Micrometers 2" and above include a standard. This product has a 1 year warranty offered by Fowler High Precision. If you experience any problem contact Fowler directly for warranty claims. Specifications Display type Vernier Anvil/spindle style Flat Measuring range 1-2†Graduation interval 0.001" Accuracy 0.00016†Thimble style Ratchet Anvil/spindle diameter 0.256" Flatness 0.00003" Parallelism 0.00008" Micrometers are precision measuring instruments that use a calibrated screw to measure distances. These measurements are translated into large rotations of the screw that are then able to be read from a scale or a dial. Micrometers are typically used in manufacturing, machining, and mechanical engineering. There are th...
-
4.0 of 5.0 with 1 Reviews
SALE PRICE: $49.35
Manufacturer: Fred V. Fowler Company, Inc.
Brand: Fowler
Model: 52-585-020-0
Manufacturer: Fred V. Fowler Company, Inc.
Brand: Fowler
Model: 52-585-020-0
The Fowler 54-565-233 High-Accuracy Ultima Bore Gauging System has a measurement range of 7.878 to 8.27" and is accurate to + or - 0.00006". Resolution is 0.00001" and the measuring depth is 3.15". The gauge has constant spring pressure for repeatability and Bower's FastFit measuring heads for rapid measurement. It uses a three-point contact system for the detection of lobing or triangular form error, and ceramic contact points provide high durability and stability with regard to thermal expansion. The Ultima system requires connection to a Sylvac or multiplexer display unit.This product has 1 year warranty offered by Fowler High Precision. If you experience any problem contact Fowler directly for warranty claims.
-
4.0 of 5.0 with 17 Reviews
SALE PRICE: $49.99
-
4.0 of 5.0 with 4 Reviews
SALE PRICE: $53.76 1% OFF
Manufacturer: e*thirteen components
Brand: e*thirteen
Model: e*thirteen components
Color: Black
Manufacturer: e*thirteen components
Brand: e*thirteen
Model: e*thirteen components
Color: Black
Back before the age of derailleurs, dudes had to climb alpine passes on singlespeeds with a flippable rear wheel that had two cogs: big and bigger. Fast forward nearly a century, and e*thirteen components' Extended Range Cog bumps your one-by drivetrain's cassette range up to the granniest of granny gearings, effectively adding a chainring to the bottom end of your cogs. With a capacity of 40 or 42 teeth, the Extended Range Cog levels the grade to make sure you get to the top without crunching all the cartilage out of your knees.
-
4.0 of 5.0 with 18 Reviews
SALE PRICE: $54.29 1% OFF
Manufacturer: ABS Import Tools
Brand: HHIP
Manufacturer: ABS Import Tools
Brand: HHIP
.001 GRADUATION | .100 PER REVOLUTION | Graduation of 0.001" in one revolution. | Inverted covered rack prevents dirt for prolonged life. | Hardened and ground stainless steel with satin chromed. | Shock proof. | 4-way measurement: inside, outside, depth
-
4.0 of 5.0 with 1 Reviews
SALE PRICE: $55.17
Manufacturer: Fred V. Fowler Company, Inc.
Brand: Fowler
Model: 52-630-460-0
Manufacturer: Fred V. Fowler Company, Inc.
Brand: Fowler
Model: 52-630-460-0
The Fowler 54-565-233 High-Accuracy Ultima Bore Gauging System has a measurement range of 7.878 to 8.27" and is accurate to + or - 0.00006". Resolution is 0.00001" and the measuring depth is 3.15". The gauge has constant spring pressure for repeatability and Bower's FastFit measuring heads for rapid measurement. It uses a three-point contact system for the detection of lobing or triangular form error, and ceramic contact points provide high durability and stability with regard to thermal expansion. The Ultima system requires connection to a Sylvac or multiplexer display unit.This product has 1 year warranty offered by Fowler High Precision. If you experience any problem contact Fowler directly for warranty claims.
-
4.0 of 5.0 with 25 Reviews
SALE PRICE: $57.99 5% OFF
Manufacturer: Fred V. Fowler Company, Inc.
Brand: Fowler
Model: 72-641-300
Manufacturer: Fred V. Fowler Company, Inc.
Brand: Fowler
Model: 72-641-300
Fowler Flex Arm Base and Indicator Combo.
|
|