|
|
-
4.9 of 5.0 with 41 Reviews
SALE PRICE: $84.57 5% OFF
Manufacturer: DeFelsko Corporation
Brand: DeFelsko
Model: STDP2
Manufacturer: DeFelsko Corporation
Brand: DeFelsko
Model: STDP2
|
Certified coating thickness standards are ideal for verifying the accuracy and operation of coating thickness gages and are an important component in fulfilling both ISO and in-house quality control requirements. Many organizations require verification of gage accuracy at the test site each time a coating thickness gage is put into service and at frequent intervals during use. Ideal for this purpose, Defelsko certified coating thickness standards have measured values traceable to a national metrology institution. Used to verify the accuracy and operation of any type 1 (mechanical) and type 2 (electronic) magnetic, eddy-current or ultrasonic coating thickness gage. Ideal for use in the calibration lab, in the field or on the factory floor. Polystyrene thickness standards consist of 4 blocks supplied in a rugged acrylic storage box. Individually serialized for traceability to NIST or PTB - includes a certificate of calibration. Certified and labeled in both metric and imperial units. Defelsko P series polystyrene block. For PosiTector 6000 FHS, NHS and EOC. Approximate thickness: 2.5mm / 100 mils for plate 1; 6.5mm / 250 mils for plate 2; 13mm / 500 mils for plate 3; 19mm / 750 mils for plate 4. Coating/substrate: polystyrene blocks. Accuracy: +/- (2.5 micrometer + 0.05 percent of thickness); +/- (0.1 mil + 0.05 percent of thickness). Measures 2-3/4" length by 1-1/2" width.
-
4.9 of 5.0 with 41 Reviews
SALE PRICE: $84.57 5% OFF
Manufacturer: DeFelsko Corporation
Brand: DeFelsko
Model: STDP2
Manufacturer: DeFelsko Corporation
Brand: DeFelsko
Model: STDP2
|
Certified coating thickness standards are ideal for verifying the accuracy and operation of coating thickness gages and are an important component in fulfilling both ISO and in-house quality control requirements. Many organizations require verification of gage accuracy at the test site each time a coating thickness gage is put into service and at frequent intervals during use. Ideal for this purpose, Defelsko certified coating thickness standards have measured values traceable to a national metrology institution. Used to verify the accuracy and operation of any type 1 (mechanical) and type 2 (electronic) magnetic, eddy-current or ultrasonic coating thickness gage. Ideal for use in the calibration lab, in the field or on the factory floor. Polystyrene thickness standards consist of 4 blocks supplied in a rugged acrylic storage box. Individually serialized for traceability to NIST or PTB - includes a certificate of calibration. Certified and labeled in both metric and imperial units. Defelsko P series polystyrene block. For PosiTector 6000 FHS, NHS and EOC. Approximate thickness: 2.5mm / 100 mils for plate 1; 6.5mm / 250 mils for plate 2; 13mm / 500 mils for plate 3; 19mm / 750 mils for plate 4. Coating/substrate: polystyrene blocks. Accuracy: +/- (2.5 micrometer + 0.05 percent of thickness); +/- (0.1 mil + 0.05 percent of thickness). Measures 2-3/4" length by 1-1/2" width.
-
4.9 of 5.0 with 32 Reviews
SALE PRICE: $84.65
Manufacturer: Ohaus
Brand: Ohaus
Model: 80780285
Manufacturer: Ohaus
Brand: Ohaus
Model: 80780285
|
The Ohaus metric, stainless steel calibration weight meets International Organization of Legal Metrology (OIML) Class E2 specifications and designed for calibrating other weights, or electronic balances and scales. The weight is constructed of stainless steel for stability, resistance to corrosion, and low magnetic susceptibility. The weight meets OIML R111 Class E2 specifications for use as a reference standard calibrating other weights, and calibrating high precision analytical balances with readabilities as low as 0.1mg to 0.01mg. The National Voluntary Laboratory Accreditation Program (NVLAP) accredits laboratories for compliance with ISO/IEC 17025 on the basis of their ability to meet the technical requirements set forth in NIST Handbook 150-2, and can provide accreditation to ANSI/NCSL Z540-1-1994. NVLAP calibrations and certifications meet all ISO, FDA, GMP, GLP, DOD, ANSI/NCSL Z540-1 and Nuclear requirements and are traceable to NIST. Procedures and processes used to generate this multi-page certificate, as well as its format and content, are prescribed by NVLAP. The document contains customer name & address, date of calibration, equipment and standards used in the calibration, accuracy class, true mass value (mass in a vacuum), “As Found†mass correction (for recalibration), “As Left†mass correction, uncertainty of measurement process (uncertainty to tolerance ratios are guaranteed), environmental conditions during test, construction and density of the weight, calibration procedure, and a statement of traceability to NIST. Mutual recognition arrangements include The International Laboratory Accreditation Cooperation (ILAC), The Asia Pacific Laboratory Accreditation Cooperation (APLAC) and The National Cooperation for Laboratory Accreditation (NACLA). Calibration weights are used to measure the weight or mass of an object using a balance or scale, or to calibrate other weights or instruments. Calibration weights can be certified or uncertified. Certified weights meet strict guidel...
-
4.9 of 5.0 with 41 Reviews
SALE PRICE: $85.47
Manufacturer: Rice Lake
Brand: Rice Lake
Manufacturer: Rice Lake
Brand: Rice Lake
|
The Rice Lake metric precision test weight is constructed of polished stainless steel, meets American Society for Testing and Materials (ASTM) Class 1 specifications, has a 7.95 density, and is designed for a variety of weighing operations. The weight can be adjusted by attaching other weights to the screw-knob. The weight is constructed of polished stainless steel for stability, resistance to corrosion, and low magnetic susceptibility, and a polished surface highlights wear that can affect weight precision. The set includes a precision test weight, a handling glove, and a protective case. The weight meets ASTM E617, Class 1 specification for use as a reference standard for calibrating other weights and high-precision balances with readabilities as low as 0.1mg to 0.01mg.Calibration weights are used to measure the weight or mass of an object using a balance or scale, or to calibrate other weights or instruments. Calibration weights can be certified or uncertified. Certified weights meet strict guidelines for accuracy and can usually be recertified. Certified weights are used in labs where a high degree of accuracy and repeatability is required. Uncertified weights are used where a lower degree of accuracy is required, including student laboratories, rough weighting operations, and measuring force. Hooked and slotted weights are often used to measure pressure, torque, and tensile strength, and to demonstrate basic laws of physics. Calibration weights differ from lab weights, which are general purpose weights used to hold an object in place, similar to a paperweight. Science education products incorporate applied math and science principles into classroom projects. Teachers in pre-K, elementary, and secondary classrooms use science education kits and products alongside science, technology, engineering, and math (STEM) curriculum to demonstrate STEM concepts and real-world applications through hands-on activities. Science education projects include a broad range of activities, such as practical experiments in engine...
-
4.9 of 5.0 with 31 Reviews
SALE PRICE: $88.58 1% OFF
Manufacturer: Mitutoyo
Brand: Mitutoyo
Model: 613198-541
Manufacturer: Mitutoyo
Brand: Mitutoyo
Model: 613198-541
|
The Mitutoyo grade AS-1 rectangular gage block is made of ceramic, has its nominal length engraved in inches, and is supplied with a Mitutoyo inspection certificate that states that the block meets American Society of Mechanical Engineers (ASME) B89.1.9-2002 grade standard for flatness, length, parallelism, and surface finish. The inspection certificate specifies the deviation of the individual block from its nominal length. Gage blocks are commonly used to calibrate fixtures and precision instruments in workshop, inspection, and dimensional metrology applications, to inspect tools such as mounting tools, cutters, fixtures, and mechanical parts, and in the gage manufacturing process itself. The grade AS-1 gage block is commonly used for workshop and inspection applications to calibrate fixtures and precision instruments, to inspect a variety of tools such as mounting tools, cutters, fixtures, and mechanical parts, and for manufacturing gage applications. It is made of ceramic which resists corrosion, abrasion, and burrs, withstands high temperatures without melting (high thermal expansion resistance), and provides dimensional stability. This gage block has a rectangular base for accurate wringing. Nominal length is measured in inches, and is indicated with laser-etched, black characters. The length of a gage block is usually slightly shorter than its stamped nominal length, to account for the thin layer of oil or wring film used when two or more blocks are wrung together. An identification number is laser-etched on the block for traceability. The block has a depth of 0.355 inches. It comes in a carrying case with a padded, formed interior. This gage block is supplied with a Mitutoyo inspection certificate [National Institute of Standards in Engineering (NIST)-traceable] that the block meets ASME B89.1.9-2002 standard for flatness, length, parallelism, and surface finish. Gage blocks (also called gauge blocks, Hoke blocks, Jo blocks, slip gages, and Johansson gages) are blocks used to calibrate measuring equipment...
-
4.9 of 5.0 with 17 Reviews
SALE PRICE: $89.77 5% OFF
Manufacturer: Ohaus
Brand: Ohaus
Model: 80780100
Manufacturer: Ohaus
Brand: Ohaus
Model: 80780100
|
Ohaus metric, American Society for Testing and Materials (ASTM) Class 4, stainless steel leaf-style calibration weight has a turned-up end to enable lifting, and is designed for calibration or for use with microbalances. The set of 12 weights is constructed of stainless steel for stability, resistance to corrosion, and low magnetic susceptibility. The weight meets ASTM E617, Class 4 specification for use as a reference standard for calibrating semi-analytic balances, and for student use. The set includes two each of the 200mg, 20mg, and 2mg weights, and one each of the 500mg, 100mg, 50mg, 10mg, 5mg, and 1mg weights, tweezers, and a covered box. The National Voluntary Laboratory Accreditation Program (NVLAP) accredits laboratories for compliance with ISO/IEC 17025 on the basis of their ability to meet the technical requirements set forth in NIST Handbook 150-2, and can provide accreditation to ANSI/NCSL Z540-1-1994. NVLAP calibrations and certifications meet all ISO, FDA, GMP, GLP, DOD, ANSI/NCSL Z540-1 and Nuclear requirements and are traceable to NIST. Procedures and processes used to generate this multi-page certificate, as well as its format and content, are prescribed by NVLAP. The document contains customer name & address, date of calibration, equipment and standards used in the calibration, accuracy class, true mass value (mass in a vacuum), “As Found†mass correction (for recalibration), “As Left†mass correction, uncertainty of measurement process (uncertainty to tolerance ratios are guaranteed), environmental conditions during test, construction and density of the weight, calibration procedure, and a statement of traceability to NIST. Mutual recognition arrangements include The International Laboratory Accreditation Cooperation (ILAC), The Asia Pacific Laboratory Accreditation Cooperation (APLAC) and The National Cooperation for Laboratory Accreditation (NACLA). Calibration weights are used to measure the weight or mass of an object using a balance or scale, or to calibrate other ...
-
4.9 of 5.0 with 32 Reviews
SALE PRICE: $89.88 1% OFF
Manufacturer: Grundens
Brand: Grundens
Color: Black
Manufacturer: Grundens
Brand: Grundens
Color: Black
Grundens Weather Gage Jacket WJ200 Non Hooded- Softshell is a unique fabric that offers the protection and abrasion resistance of a shell, with the soft and easy wearing of a fleece. These fabric features are combined with a water repellent and breathable membrane to provide a jacket suitable for all but the most extreme weather conditions. The Weather Gage jacket has water repellent zippers and a nice high collar. The cinch cord hem controls also lead into the hand warmer pockets. There is a large napoleon pocket on the outside with a water repellent zipper and a large inner chest pocket that is MP3 friendly with a exit for a headphone jack. The wrists have a velcro tab for cinching tight. Sizes and colors available as displayed.
-
4.9 of 5.0 with 15 Reviews
SALE PRICE: $90.97 1% OFF
Manufacturer: Hexagon Metrology
Brand: Standard Gage
Manufacturer: Hexagon Metrology
Brand: Standard Gage
-
4.9 of 5.0 with 18 Reviews
SALE PRICE: $92.50
Manufacturer: Woodcraft Supply
Brand: WoodRiver
Manufacturer: Woodcraft Supply
Brand: WoodRiver
Usually only found in machine shops, the super flat face of the granite surface plate is ideal for leveling small plane beds, flattening waterstones and general sharpening duties. Simply soak a piece of wet/dry sandpaper in water and lay it down on the stone; the capillary action of the water adheres the paper to the stone, eliminating the need for spray adhesives or PSA sandpaper. When done, wipe clean with a paper towel. This A grade plate measures 12" x 18" x 3", weighs 80 lbs. and comes with a surface map. Plate does not have ledges.
-
4.9 of 5.0 with 4 Reviews
SALE PRICE: $93.70 1% OFF
Manufacturer: Ohaus
Brand: Ohaus
Model: 80780333
Manufacturer: Ohaus
Brand: Ohaus
Model: 80780333
|
The Ohaus metric, stainless steel calibration weight meets International Organization of Legal Metrology (OIML) Class F1 specifications and designed for calibrating other weights, or electronic balances and scales. The weight is constructed of stainless steel for stability, resistance to corrosion, and low magnetic susceptibility. The weight meets OIML R111 Class F1 specifications for use calibrating high-precision top loading balances with a readability as low as 0.01g to 0.001g.The National Voluntary Laboratory Accreditation Program (NVLAP) accredits laboratories for compliance with ISO/IEC 17025 on the basis of their ability to meet the technical requirements set forth in NIST Handbook 150-2, and can provide accreditation to ANSI/NCSL Z540-1-1994. NVLAP calibrations and certifications meet all ISO, FDA, GMP, GLP, DOD, ANSI/NCSL Z540-1 and Nuclear requirements and are traceable to NIST. Procedures and processes used to generate this multi-page certificate, as well as its format and content, are prescribed by NVLAP. The document contains customer name & address, date of calibration, equipment and standards used in the calibration, accuracy class, true mass value (mass in a vacuum), “As Found†mass correction (for recalibration), “As Left†mass correction, uncertainty of measurement process (uncertainty to tolerance ratios are guaranteed), environmental conditions during test, construction and density of the weight, calibration procedure, and a statement of traceability to NIST. Mutual recognition arrangements include The International Laboratory Accreditation Cooperation (ILAC), The Asia Pacific Laboratory Accreditation Cooperation (APLAC) and The National Cooperation for Laboratory Accreditation (NACLA). Calibration weights are used to measure the weight or mass of an object using a balance or scale, or to calibrate other weights or instruments. Calibration weights can be certified or uncertified. Certified weights meet strict guidelines for accuracy and can usually be recertified. Certi...
|
|